Daikin ATM18MV2S 서비스 매뉴얼 - 페이지 7

{카테고리_이름} Daikin ATM18MV2S에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Daikin ATM18MV2S 20 페이지. Removal procedure, 5.0/6.0/7.1 kw class, 15000/18000 btu/h class
Daikin ATM18MV2S에 대해서도 마찬가지입니다: 서비스 매뉴얼 (20 페이지)

Daikin ATM18MV2S 서비스 매뉴얼
Si041254EE

4. Horizontal Blades

Warning
Step
1
Bend the horizontal
blade (lower) slightly
and release the 2
center shafts.
2
Release the left shaft.
3
Slide the horizontal
blade (lower) to the left
and release the right
shaft.
4
Remove the horizontal
blade (upper) in the
same way.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Left shaft
Center shaft
Horizontal blade
(upper)
Horizontal blade
(lower)
(R21152)
Right shaft
(R2766)
Horizontal Blades
Points
When reassembling, mount
the large horizontal blade to
the upper position and the
small horizontal blade to the
lower position.
Installation procedure
1. Fit the horizontal blade to the
right shaft first. Make sure to
rotate the horizontal blade so
the shaft fits correctly.
2. Fit the horizontal blade to the
center and left shafts.
5