10.Fan Motor / Fan Rotor
Warning
Step
1
Remove the 2 screws.
2
Lift and remove the
right side plate.
3
Remove the screw, and
then the fan motor
fixing plate.
4
Loosen the screw of the
fan rotor.
5
Remove the fan motor.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Fan rotor
Right
side
plate
(R16544)
Fan motor fixing plate
Side face of rotor
(R2805)
(R2806)
(1) Insert the fan motor allowing
(2) Tighten the fan rotor screw
(3) If the fan rotor rotates
Fan motor
(4) If not, repeat the procedure
(R12897)
Fan Motor / Fan Rotor
Points
You can remove the fan
rotor without detaching the
right side plate.
When reassembling the fan
motor and the fan rotor,
provide as much as 5 mm
(0.2 inch) of play between
the side face of the rotor and
the bottom frame.
Side face of
bottom frame
5 mm (0.2 inch)
(R18879)
(R9582)
for approx. 5 mm (0.2 inch)
of play.
until it stops. Then give the
screw one more turn.
appropriately, tighten the
screw completely.
from (1).