Installation
1
Carefully unpack unit from its packaging. Properly
inspect for defects before installing. Wear work
gloves to prevent dirt and oil from being
transferred to the luminaire.
Bend clips
3
Bend the 4 clips to secure the luminaire in place.
Install the safety cables through the holes on the clips
(per local building codes, safety cables by others).
Electrical Connections
Risque de choc électrique. Couper l'alimentation avant le dépannage ou avant l'installation du produit.
WHITEC
BLACK
GROUND
GREY
VIOLET
Safety cable
WARNING/AVERTISSEMENT
Risk of electrical shock. Disconnect power before servicing or installing product.
120-277V
OMMON
NEUTRAL
UNSWITCHED
LINE
GROUND
DIMMING (••)
DIMMING
0-10V
DIMMING (+)
2
Install the unit into the reserved hole in the ceiling.
If installing more than one luminaire per room,
follow instructions on the diffuser label to maintain
consistent orientation.
NOTE: Two sets of leads may be provided from the recessed
troffer module labeled "UV" and "WHITE." These may be
connected to the same or separate circuits depending on
customer instruction.