Daishiba DSP?100HA 설치 및 운영 매뉴얼 - 페이지 14
{카테고리_이름} Daishiba DSP?100HA에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Daishiba DSP?100HA 17 페이지. Air source swimming pool heat pump
Press the "Inquiry" button 10 seconds, enter into the parameter setting state of the
administrative class
Parameter Instruction
P01
Back temp adjustment
P02
Temp precision adjustment
Heating water flow insufficient temp.
P03
difference protection adjustment
Cooling water flow insufficient temp.
P04
difference protection adjustment
P05
Entering defrosting temp. adjustment
P06
Defrosting end temp. adjustment
P07
Defrosting interval time adjustment
P08
Defrosting running time adjustment
Compressor exhaust protection temp.
P09
adjustment
P10
low pressure time set
low pressure environment temp.
P11
adjustment
Over
P12
adjustment
Overheating
P13
adjustment
P12
P14
protection times adjustment 0‐5
Selecting of restart function when
P50
outage
Background light selecting of the
P51
display screen
cool
protection
protection
and
P13
unrecoverable
Range
1 ‐ 15℃
‐5 ‐ 15℃
5‐ 60℃
5 ‐ 60℃
‐5 ‐ 7℃
2‐ 25℃
20 ‐ 80 min
3 ‐ 15 min
100 ‐ 125℃
1‐15min
‐10‐0℃
temp.
1‐15℃
temp.
50‐85℃
0 ‐ 5
0[No] 1[Yes]
1[light 15s]
0[light
constantly]
- 13 -
Default
Mark
3℃
0℃
15℃
12℃
‐2℃
12℃
45min
6min
Adjust
110℃
through
5min
"up/down
" button
‐5℃
5℃
65℃
3
1
1