ANSI PCGS 18FTLE-SK 사용자 사용 설명서 - 페이지 4

{카테고리_이름} ANSI PCGS 18FTLE-SK에 대한 사용자 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. ANSI PCGS 18FTLE-SK 14 페이지.

Installation and use
Ensure that the structural anchor to which Electron Tie-Back SRL is to be attached, and on which work is to be performed, is free
Ÿ
of all hazards, including, but not limited to, debris, rot, rust, sharp or abrasive edges and surfaces, and hazardous materials.
Wrap Tie- Back SRL lifeline around selected structural anchor, and attach snap hook on to webbing below shock pack (Never
Ÿ
attach snap hook between housing and shock pack). Attach Electron Tie-back carabiner to applicable harness D-ring.
WARNING:
If the Electron with rebar hook conguration is used, then the rebar hook should always be connected to the anchorage
structure, and NEVER to the dorsal D-ring of the full body harness. And the Electron casing should always be worn at the
harness end. A competent person must always ensure compatibility of the anchorage structure with the Electron.
5.
GENERAL REQUIREMENTS, WARNINGS AND LIMITATIONS:
The Equipment is designed for use as a part of a personal fall protection system. Components must not be used for any other
Ÿ
operation other than that which it has been designed and approved. Fall Arrest system are designed to comply with OSHA. Fall
Restraint System must be designed by a Qualied Person, and must be installed and used under the supervision of a competent
person.
All authorized persons/users must refer the regulations governing occupational safety, as well as applicable ANSI or CSA
Ÿ
standards. Please refer to product labeling for information on specic OSHA regulations, ANSI and CSA standards met by
product.
Proper precautions should always be taken to remove any obstructions, debris, material, or other recognized hazards from the
Ÿ
work area that could cause injuries or interfere the operations of the system. All equipment must be inspected before each use
according to the manufacturer's instructions. All equipment should be inspected by a qualied person on a regular basis.
Ÿ
To minimize the potential for accidental disengagement, a competent person must ensure system compatibility.
Equipment must not be altered in any way. Repairs must be performed only by the manufacturer, or persons or entities authorized
Ÿ
in writing by the manufacturer.
Any product exhibiting deformities, unusual wear, or deterioration must be immediately discarded. Any equipment subject to a
Ÿ
fall must be removed from service. The authorized person/user must have a rescue plan and the means at hand to implement it
when using this equipment.
Never use fall protection equipment for purposes other than those for which it is designed. Fall protection equipment should never
Ÿ
be used for towing or hoisting.
Ÿ
All synthetic material must be protected from slag, hot sparks, open ames, or other heat sources. The use of heat resistant
materials is recommended in these applications.
Never use natural materials (manila, cotton, etc.) as part of a fall protection system.
Ÿ
Do not expose this equipment to chemicals which may have a harmful effect on the materials used to construct it. Be especially
Ÿ
aware of caustic environment, or those that contain high levels of organic acids or bases. If you are uncertain about the safe
3
Structural Anchor (I –beam)
Snap Hook
Shock Pack
To this eye hole, attach
carabiner to applicable harness