3. Programming

IMPORTANT: the device does not need to be placed close to the control panel for recognition programming. In fact, we advise you to
move the product at least 2 metres away from the control panel.
This operation allows the control panel to recognise the detector.
1. For detector recognition programming, the control panel must be in installation mode. If it is not, ask the user to enter:
master code (factory: 0000)
2. Proceed as follows for recognition programming:
then
Press and hold the "test"
Press
then
on
#
*
button until the control
the control panel
panel responds.
keypad.
IMPORTANT: the control panel issues three short beeps to indicate a programming error. When this happens, programming must
be performed again from the beginning.
then
installer code (factory: 1111)
"detector X"
"group ?"
* depending on the type
10 s max.
Select the group from 1 to
8*. Use the control panel
keypad to do this.
"time delay?"
*
to
to
of control panel
Select the time delay:
0: immediate
1: delayed
2: combined
Use the control panel
keypad to do this.
54
"beep, installation
mode"
"beep, detector X,
group Y, immediate
(or delayed
or combined)"
The control panel
issues a voice
message to confirm
detector recognition
programming.