DAITEM SH148AX 설치 매뉴얼 - 페이지 11

{카테고리_이름} DAITEM SH148AX에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DAITEM SH148AX 18 페이지. Outdoor ir anti-masking 5 m

7.3 Setting the operating options

The options are set using the 6 dip switches inside the detection module.
Operating option
LED indicator
dip switches
IMPORTANT: if you position dip switch 2 or
dip switch 4 to ON, the battery life will be
shortened.
ON
Detector in test mode
The LED lights up each time something is detected making it possible to test the range.
1 2 3 4 5 6
Detector in normal user mode (factory setting)
ON
The LED remains unlit (unless dip switch n° 4 is ON). The frequency of radio message
transmission depends on the position of dip switch n° 2.
1 2 3 4 5 6
Triggering time delay
ON
Set for 5 s, even when something is permanently detected, the radio transmission is only
activated once every 5 s.
1 2 3 4 5 6
Triggering time delay (factory setting)
ON
Set for 120 s, even when something is permanently detected, the radio transmission is only
activated once every 120 s. Position recommended if there is frequent activity inside the
1 2 3 4 5 6
detection zone.
ON
Mandatory position (factory setting)
1 2 3 4 5 6
ON
LED indicator status selection
The LED lights up with every detection
1 2 3 4 5 6
LED indicator status selection (factory setting)
ON
The LED does not light up with every detection (unless dip switch n°1 is ON).
Position recommended if there is frequent activity inside the detection zone.
1 2 3 4 5 6
ON
Normal detector sensitivity (factory setting)
This setting is suitable for most installations.
1 2 3 4 5 6
Low detector sensitivity
ON
This setting is recommended for difficult environmental conditions (wind, reflecting ground,
high brightness level, etc.)
1 2 3 4 5 6
Anti-masking function enabled (factory setting)
ON
If the device is masked, the LED indicator flashes 3 times in a row every 5 seconds throughout
the duration of the fault (if dip switch n° 4 is ON).
1 2 3 4 5 6
ON
Anti-masking function disabled
1 2 3 4 5 6
factory setting
25