2. Features
2-1
Input voltage
・ Input voltage range is single phase alternating
current. 85~264Vac(47~63Hz).
・ We recommend that you do not use this power
supply unit outside of it's normal intended use in
order to avoid any damage or malfunctions.
2-2
Output voltage setting
・ You can adjust +Vout by using Output Voltage
Adjustment Potentiometer that is next to the
connector (CN501).
・ You can increase output voltage by turning clockwise.
If you need decrease, you can turn it the other way.
・ Please use it within the following range when you
adjust the output voltage.
・Within +/- 10% rated output voltage.
・Do not use maximum output power.
・ Do not exceed rated output current.
2-5
Over-Voltage Protection(OVP)
It detects when the output voltage exceeds by some
reasons, and the output is intercepted at once.
When it works once, the over-voltage protection
continues the output interception while the input is
supplied.
Turn it on again after a few minutes after intercepting
the input when resetting it.
Note that the output voltage might be abnormal when
you turn it on again. (In this case, the over voltage
protection works again. )
2-7
Over Temperature Protection (OTP)
It detects internal components temperature abnormally
getting higher, then turn off the output.
Once it detects and stops output, it stops supplying the
output even AC input supplies.
In order to reset this, please disconnect AC input, then
confirm well cooling down the temperature inside the PSU
after several minutes. Then please apply AC input. Also
please confirm the forced air convection would well enough
to meet the air flow condition.
2-3
Inrush Current
・ The inrush current limiting circuit is built-in.
・ The inrush current limiting circuit might released it
when the input re-turning on time is short, because
SCR is used for the inrush current limiting. So turn it
on again enough after time.
・ The first inrush current and the second inrush
current flow because it adopts SCR method for the
inrush current limiting circuit.
2-4
Over-current Protection(OCP)
・ The over-current protection works and the output is
intercepted when becoming 110% or more of the
output current ratings.
・ Remove the factor of the overload, and turn on the
input again after a few minutes of cutting when
resetting it.
・ Please avoid operation in the over-current state
for 10 seconds or more.
It will cause damage or isolation failure.
2-6
Remote Sensing
Please use within 0.3V voltage drop range to adjust.
Then, please set up the output voltage range won't
exceed voltage range we specify.
Please twist the wires and install just besides in parallel
with wires for load as shown below.
Power
Note: We connected with wires between Pin#1 & Pin#2,
Also Pin #3 & Pin#4 as a default settings when we ship
from factory. This setting is for the customers who won't
use remote sensing feature. So, if you need to use this
feature, 1) Please remove the existing wires 2) Use
twisted cable for this feature to use shown as above.