DSC LC-104PIMW 설치 지침 - 페이지 2

{카테고리_이름} DSC LC-104PIMW에 대한 설치 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. DSC LC-104PIMW 2 페이지. Passive infrared & microwave motion detector with pet immunity

DSC LC-104PIMW 설치 지침
SETTING - UP THE DETECTOR
MW SENSITIVITY ADJUSTMENT:
Switch 3 of DIP-5. Use for Setting "MW" - provides sensitivity control of MW (DOPPLER) according to the environment. Position Down "OFF" -
High sensitivity F or nor mal operation - immediate detec tion. Posit io n Up "ON" - L ow sensitivity F or har sh envi ronments.
POTENTIOMETER "MW" - adjustment according to protected area range. The potentiometer at mid-scale is equivalent to a distance of 15m, at min-
scale - 7m. Rotate the potentiometer clockwise to increase range, counter-clockwise to decrease range.
NOTE: Dimension change according to installation location and room size.
PIR SENSITIVITY ADJUSTMENT:
Switch 2 of DIP-5. Use for Setting "PIR" - provides sensitivity control of PIR according to the environment.
Position Down "OFF" - High sensitivity For stable envir onments. Position Up "ON" - Low sensitivity For harsh environments.
POTENTIOMETER "PIR" - adjustment according to protected area range. Use "PIR" to adjust the detection range between 68% and 100% (factory
set to 84%). Rotate the potentiometer clockwise to increase range, counter-clockwise to decrease range.
PET IMMUNITY SETTING:
Switch 4 of DIP-5. Use for Setting "PET" 15kg - 25kg
Po sition Up "O N" - Immunity to an animal up to 15 kg. Posit io n Do wn " OFF " - Immunity to an animal up to 25 kg.
Switch 1 of DIP-5. Use for Setting: "LED" - LED Enable / Disable.
Position On - LED ENABLE The RED LED will activate when the detector is in alarm condition.
Position Off - LED DISABLE The LEDS are disabled.
Note: the state of the switch "LED" does not affect the operation of the relay. When an intrusion is detected, the LED will activate and the alarm relay
will switch into alarm condition for 2 sec.
LED INDICATORS:
YELLOW LED - MW detection's. GREEN LED - PIR detection's. RED LED - Alarm
ALARM MODE SETTING:
Switch 5 of DIP5. Use for Setting the mode of the detector. Position Dowen - OFF "AND" - The alarm signal occurred only when both sensor
signals (PIR & MW) are present at the same time.
Posit ion Up -ON "OR" - The alarm signal (relay activation) occurred when one of the sensors signals ( PIR & MW) is present.
NOTE: You must reset the detector from Control Panel before the new settings will take effect.
TEST PROCEDURE:
Wait for one minute warm up time after applying 12 Vdc power. Conduct testing with the protected area cleared of all people. Walk test 1. Remove
front cover. Set LED to ON position. 2. Reassemble the front cover. 3. Start walking slowly across the detection zone. 4. Observe that the red LED
lights whenever motion is detected. 5. Allow 5 sec. between each test for the detector to stabilize. 6. After the walk test is completed, you can set the
LED to OFF position.
NOT E: Wal k tests should be conducted, at least once a year, to confi rm pr oper operation and coverage of the detector.
TECHNICAL SPECIFICATION
Detection Method:
Quad element PIR & microwave
pulse Doppler
Power Input:
8.2 to 16 Vdc
Current Draw
Active: 25.5 mA
Standby: 16.5 mA
Temp.
Compensation:
YES
Alarm Period:
2 +/- 1 sec
Alarm Output:
N.C 28Vdc 0.1 A with 10 Ohm series
protection resistors
Tamper Switch:
N.C 28Vdc 0.1A with 10 Ohm series
protection resistor - open when
cover is removed
Warm Up Period:
1 min
LED Indicator:
Yellow & Green LEDs are blinking
during warm up period and self testing
Red LED: ON during alarm
Green LED: PIR CHANNEL
Yellow LED: MW CHANNEL
Dimensions:
118mm x 62.5mm x 40mm
(4.65" x 2.46" x1.61")
Weight:
120 gr.
LIMITED WARRANTY: Digital Security Controls Ltd, warrants that for a period of 12 months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use and that in fulfillment of any
breach of such warranty. Digital Security Controls Ltd shall, at its option, repair or replace the defective equipment upon returns of the equipment to its repair depot. This warranty applies only to defects in parts and workmanship and not to
damage incurred in shipping or handling, or damage due to causes beyond the control of Digital Security Controls Ltd, such as lightning, excessive voltage mechanical shock, water damage, or damage arising out of abuse, alteration or
improper application of the equipment.
The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Ltd. Digital
Security Controls Ltd neither assumes responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product.
In no event shall Digital Security Controls Ltd be liable for any direct, indirect or consequential damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation or operation
or failure of this product.
Motion detectors can only detect motion within the designated areas as Shown in their respective installation instructions. They cannot discriminate between intruders and intended occupants. Motion detectors do not provide volumetric area
protection. They have multiple beams of detection and motion can only be detected in unobstructed areas covered by these beams. They cannot detect motion which occurs behind walls, ceilings, floor, closed doors, glass partitions, glass
doors or windows. Any
type of tampering whether intentional or unintentional such as masking , painting, or spraying of any material on the lenses, mirrors, windows or any other part of the detection system will impair its proper operation.
Passive infrared motion detectors operate by sensing changes in temperature. However their effectiveness can be reduced when the ambient temperature rises near or above body temperature or if there are intentional or unintentional sources
of heat in or near the detection area. Some of these heat sources could be heaters, radiators, stoves, barbeques, fireplaces, sunlight, steam vents, lighting and so on.
WARNING: Digital Security Controls Ltd, recommends that the entire system be completely tested on a regular basis. However, despite frequent testing, and d ue to, but not limited to, criminal tampering or electrical disruption,
it is possible for this product to fail to perform as expected.
Imp o rtan t info rmatio n: Ch ang es o r mo di fi cation s n ot exp ressl y ap pro ved by D igi ta l Secu rity Co ntrol s Ltd cou ld voi d th e use r's au th ori ty to op erate thi s eq uip men t.
2005 Digital Security Controls Ltd
Toronto, Canada
www.dsc.com
FIG 5 - PCB Layou t
BLOCK CONNECTOR
SWITCH FOR
PYROSENSOR
SETTINGS
1
3
FIG 6
Bracket Installation
Wall Mount
Ceiling Mount
2
1
Bracket
Bracket
FIG 7
Bracket options