ENGLISH
Read the installation instructions carefully before use.
ELECTRICAL SAFETY
New installations and extensions to existing systems should always be carried out by an authorised
electrician. If you have the necessary experience and knowledge, you may replace switches and power
points, fit plugs, extension cords and light sockets. If not, you should contact an electrician. Incorrect
installation can result in electric shock or fire.
Disconnect the power supply before installation and/or maintenance.
The product must be earthed.
Do not use the product if the glass cover is cracked. Replace the glass cover immediately. Use only
original spare parts.
Connect the green and yellow earth wire to the earth terminal, which is marked with the earth symbol.
Connect the live wire to the terminal marked L and the neutral wire to the terminal marked N.
Disconnect the power supply before maintenance. All maintenance work must be performed by a
qualified electrician.
The product is intended for permanent installation.
If any part of the product is damaged it must be replaced by an authorised service centre, or qualified
person, to ensure safe use.
IMPORTANT: The light source cannot be replaced. If the light source fails, the entire product must be
replaced.
1.
Do not install the product on surfaces that are exposed to vibrations.
2.
The product should be mounted with the wall bracket.
3.
Hold the wall bracket against the wall, mark out and drill the holes, and mount the wall bracket with
suitable screws (not supplied).
4.
Open the connection box.
5.
Insert the mains cable (not supplied, use cable of H05RN-F 3G 1.0 mm
box through the inlet with rubber seal. Check that the inlet is sealed.
6.
Connect the green and yellow earth wire to the earth terminal, which is marked with the earth symbol.
Connect the live wire to the terminal marked L and the neutral wire to the terminal marked N.
7.
Replace the cover on the connection box. Make sure the refit the rubber seal on the cover.
8.
Fit the product on the wall bracket with the two screws. Adjust the product to the required position
and tighten the screws.

SAFETY INSTRUCTIONS

TECHNICAL DATA

Rated voltage
Output
Colour temperature
Luminous flux
Diffusion angle
Ambient temperature
Protection rating

INSTALLATION

ENGLISH
230 V ~ 50 Hz
14 W
4000 K
1100 lm
60º
-25 – +40°C
IP44
NOTE:
N
Blue (neutral wire)
Yellow/green (earth wire)
L
Brown (live wire)
8
2
type) into the connection