Installation Instructions
The PC5904 Central Station Talk / Listen module is used in conjunction with the
PC5908 (software version 1.10 or higher) or PC5928 Audio Interface modules for
communication with the central monitoring station. Each PC5904 station has a
separate microphone and speaker to both transmit and receive audio input. In
addition, personnel at the monitoring station can communicate with the end user
by listening in when security problems occur and providing verbal response via
the station's speaker.
Each station must be home-run to the interface module using shielded 22-gauge,
four-conductor wire.
Each station can be programmed to sound a pulsing tone whenever the system
bell or siren is activated. To program this option, refer to the PC5908/PC5928
Programming Worksheets located in the Installation Manual (Section [802],
subsection [30], option [1]).
This station does not have Do Not Disturb or Page/Answer buttons
since it is used strictly for talking and listening-in purposes. Therefore,
we recommend that it be masked off in the general broadcast mask
options. This option can be programmed for each station in PC5908/
PC5928 programming section [802], subsection [20], options [2] - [8].
Specifications
• PC5908/PC5928 current-providing capability: 500mA
• PC5904 maximum current draw: 175mA
• PC5901/PC5921 maximum current draw: 50mA
Mounting and Wiring Directions
1. Locate the desired placement of the unit. Place the PC5904 backplate against
the wall and mark the appropriate screw locations.
2. Secure the PC5904 backplate to the wall using the supplied screws. Consult
the diagram below:
TM
S E C U R I T Y
S Y S T E M
WALL
TM
Central Station Talk / Listen Module
BACKPLATE
PC5904