This equipment shall be installed in non-hazardous locations,
by service persons only. These instructions must be used with
the PC5900 Installation Manual.
The PC5904 Central Station Talk/Listen module is used in
conjunction with the PC5900 for communication with the
central monitoring station. Each PC5904 station has a separate
microphone and speaker to transmit and receive audio input.
Monitoring station personnel can listen in and respond via the
control station loud speaker when required.
Wire each station directly to the PC5900 using shielded
22-gauge, 4-conductor wire.

Specifications

• PC5904 maximum current draw: 175mA
• Operating Temperature: -10°C to +55°C
• Relative Humidity: 93% (max.)
Mounting and Wiring Directions
Prior to installation, disconnect
IMPORTANT NOTE:
power and telephone line connection.
1. Position the PC5904 backplate in the desired location and
mark the appropriate screw locations.
2. Secure the PC5904 backplate to the wall using the
supplied screws, as indicated below:
WALL
29 0 0 1 9 0 8 R0 0 4
© 2013 Tyco International Ltd. and its Respective Companies. All Rights Reserved.
Toronto, Canada www.dsc.com
Tech. Support: 1-800-387-3630 (Canada & U.S.), 905-760-3000
3. Wire the station to the PC5900. To wire the power, connect
the +VS to AUX and GND to COM (red = positive; black =
negative). The MIC and SPK terminals on each PC5904
must be connected to an M terminal (M1-M4) and a SPK
terminal on the PC5900 as indicated below:
PC5900
RED BLK YEL GRN
There are two AUX and COM terminals located on the
NOTE:
PC5900. The PC5904 can be connected to either terminal.
4. The speaker volume and microphone sensitivity can be
adjusted with the MIC and SPK potentiometers, as
indicated in the diagram above.
5. Once all wiring is complete, mount the station to the
backplate.
It is recommended that wall anchors be used for all
NOTE:
mounting screws. When the wall anchors have been installed,
secure the backplate to the wall.
BACKPLATE
AUX
COM
M1
M2
M3 M4 SPK
RNG TIP
R-1 T-1
LIMITED WARRANTY
Digital Security Controls warrants that for a period of twelve months from the
date of purchase, the product shall be free of defects in materials and workman-
ship under normal use and that in fulfillment of any breach of such warranty,
Digital Security Controls shall, at its option, repair or replace the defective
equipment upon return of the equipment to its factory. This warranty applies
only to defects in parts and workmanship and not to damage incurred in ship-
ping or handling, or damage due to causes beyond the control of Digital Secu-
rity Controls such as lightning, excessive voltage, mechanical shock, water
damage, or damage arising out of abuse, alteration or improper application of
the equipment.
The foregoing warranty shall apply only to the original buyer, and is and shall be
in lieu of any and all other warranties, whether expressed or implied and of all
other obligations or liabilities on the part of Digital Security Controls. This war-
ranty contains the entire warranty. Digital Security Controls neither assumes
responsibility for, nor authorizes any other person purporting to act on its behalf to
modify or to change this warranty, nor to assume for it any other warranty or lia-
bility concerning this product. In no event shall Digital Security Controls be liable
for any direct or indirect or consequential damages, loss of anticipated profits, loss
of time or any other losses incurred by the buyer in connection with the purchase,
installation or operation or failure of this product.
Warning: Digital Security Controls recommends that the entire system be
completely tested on a regular basis. However, despite frequent testing, and
due to, but not limited to, criminal tampering or electrical disruption, it is pos-
sible for this product to fail to perform as expected.
FCC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved by Digital Security Con-
trols could void your authority to use this equipment.
This equipment generates and uses radio frequency energy and if not installed
and used properly, in strict accordance with the manufacturer's instructions,
may cause interference to radio and television reception. It has been type tested
and found to comply with the limits for Class B device in accordance with the
specifications in Subpart "B" of Part 15 of FCC Rules, which are designed to
provide reasonable protection against such interference in any residential
installation. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause interference to television or
radio reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the
following measures:
• Re-orient the receiving antenna
• Relocate the alarm control with respect to the receiver
• Move the alarm control away from the receiver
• Connect the alarm control into a different outlet so that alarm control and
receiver are on different circuits.
If necessary, the user should consult the dealer or an experienced radio/television
technician for additional suggestions. The user may find the following booklet
prepared by the FCC useful: "How to Identify and Resolve Radio/Television
Interference Problems". This booklet is available from the U.S. Government
Printing Office, Washington D.C. 20402, Stock # 004-000-00345-4.
Printed in Canada