2.3 Errors and Warnings
The speaker will monitor constantly it's input level, positional feedback of the woofer cone, 
currents of the amplifiers, operating temperature, status of the DSP and microphone input in 
calibration. The speaker can maintain safe operation in many different situations, but might 
inform the user about these. If electromagnetic pulse disorients the DSP, a special integrated 
"watchdog" will turn the power off instantly to prevent permanent damage or misbehaviour. If 
the temperature becomes dangerously high,  the speaker will go into stand by  mode  and 
wake up only after it has cooled down to safe range. If an external force is pressing the 
woofer cone for too long, the speaker will flash the status led red, and eventually shut itself 
down if the external force persists.
2.3.1
Blinking Red Status LED
In   normal   operation,   the   blinking   status   led   simply   tells   the   user   that   the   A/D   saturation 
threshold is reached. This does not necessarily require any actions from the user, as there is 
still   about   4   dB   headroom   until   the   level   is   too   high   and   the   A/D   converter   saturates. 
However, if the sound occasionally starts to distort, it is adviceable to adjust the input gain 
control down to lower the input voltage and prevent distortion.
2.3.2 Status LED is Lit Red
When the speaker is in standby mode, the status led is red. If the status led turns to red in 
the middle of the normal operation (with input audio present), there might be failure due to 
several   reasons.   The   speaker   will   automatically   shut   down   if   it   detects   any   failure   in   its 
operation or in the sensor data. For example, if external force is pressing the woofer cone, 
the speaker will detect inconsistence between sensor and input A/D, leading eventually to 
shut down in order to prevent damage to voice coil. After failures the speaker will restart next 
time in safe mode and make some checks to return to normal operation safely. After safety 
checks, the speaker will restore normal status.
2.3.3 Thermal Shut­down
The Servo 300 speaker are also equipped with thermal sensors. If the operating temperature 
increases too much inside the speaker, it will shut down automatically. After the temperature 
is back to safe levels, the speaker will return to normal function.