DSPPA MP6906 운영 매뉴얼 - 페이지 11
{카테고리_이름} DSPPA MP6906에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DSPPA MP6906 11 페이지. Power amplifier for pa conference system
Fire brigade/PA system
*
5.
Packing List
MP69 series equipment one set, MP-P power cord one piece, connecting line (1.5 m 2-2 lotus plug
line) one piece, black filling ring 4 pieces, M5
pieces, black plastics protective cover 1 piece, Operation Manual one copy, Card of Guarantee one
sheet.
6.
Performance Specifications
Model
Rated output power
Output voltage adjust rate
Minimum power emf
Frequency response
Total harmonic distortion
S/N ratio (A weighted)
7-band equalizer
Protection function
Mute function
Phantom power
Frequency
Rating power
Power consumed
Dimensions
Gross weight
Net weight
No prior notice will be given for modification of specifications in any.
MP6906
MP6912
60W
120W
Less than 2 dB
Microphone 2.5±0.5 mV (unbalance input)
Microphone 2.5±0.5mV (balance input)
Wiring 250±50 mV
50 Hz ~ 20 KHz (±3dB)
Less than 0.5% (1 KHz, normal work condition)
Microphone:
Greater than 75 dB
Wiring:
Greater than 85 dB
64Hz:
±12dB
160Hz:
±12 dB
400Hz:
±12 dB
1KHz:
±12 dB
2.5KHz: ±12 dB
6.4KHz: ±12 dB
15KHz: ±12 dB
DC, overload, short-circuit.
Microphone 1 and chime input covering other inputs
DC24V
0-5 Hz higher than the input signal frequency
AC 220V / 50Hz
120 W
250 W
12.5 kg
16 kg
11 kg
14.9 kg
11
Conference power amplifier
18 semi circular head stainless steel screw 4
╳
MP6925
250W
500 W
430×368×88 mm
15.5 kg
14 kg
DSPPA ACOUSTIC TECHNOLOGY CO. LTD.
MP6935
350W
650 W
16.5 kg
15kg