4.2 Introduction to Main Interface
Functions:
1. Zone on/off;
2. Zone status display: four colors to indicate four different status– on, off, light load and overload;
3. Load change rate display: R% = original load/actual load*100% (Original load value: load of first-time
calibration)
Note: the error of scheduled detection, all zone detection and single zone detection for used zone is within 20%;
the error of real-time detection for unused zone is within 10%. Therefore, if the detection data changes when
performing scheduled detection, all zone detection and single zone detection, please manually turn off the zone, so
as to further confirm the detection result through real-time detection. Each time the zone is turned off for real-time
detection, wait for 30 seconds to stabilize the data before reading the test data.
Figure 2-1
4
Click to turn to
next interface as
Figure 2-2