7. Manually temperature calibra�on
7.1 In first system se�ng page ,press 1 to enter temperature calibra�on mode, and "CAL" will show
on display panel on which also shows last calibra�on value(Figure 10,calibra�on value is 0 ).
7.2 In calibra�on mode, press
and
to set calibra�on temperature values whose range is 50
~ 50
90 ~+90
.Calibra�on value will be nega�ve as actual measured temperature value is
smaller than the value showed on display panel. Calibra�on value will be posi�ve as
actual measured temperature value is bigger than the value showed on display panel.
7.3 Press #1 to store calibra�on temperature values a�er input calibra�on values.
Figure 10
Calibra�on method:
Please prepare temperature probe, measure soldering �p temperature and record it(Please add
some solder on soldering �p to let soldering �p and probe contact closely). Denote actual measured
temperature as T1(like 320 ) and denote displayed temperature value as T2(like 350 ).So
calibra�on value should be 30 (T1 T2) and then press
to input " 30".
8 Trimming func�on is turned 8.Enable fine tuning.
8.1 In system se�ng mode, press #2 to enter fine tuning se�ng mode and display panel will show
current fine tuning status now. Press
or
to enable or disable fine tuning func�on and then
press #2 to save it.
Note: As se�ng content is "ON", the fine tuning func�on is turned on which make temperature
adjusted at 1 digit for each pressing. Otherwise, temperature will be adjusted at 5 digits for each
pressing. This is quite fit for different opera�on requirements.
Figure 11
Figure 12
9. Switching temperature scales
9.1 In system se�ng mode, Press #3 to enter temperature scales se�ng mode and display panel
will show current temperature scale now. Press
or
to switch temperature scales between
Fahrenheit and Celsius, then press #3 to save it(Figure 13,Figure 14).
Figure 13
Figure 14
10. Se�ng automa�c stand by �me
10.1 In system se�ng mode, press
to go to second se�ng page(Figure 8). Then press #1 to enter
7