【DIN-Rail Mounting】
The product adopts 35mm standard DIN-Rail mounting which
is suitable for most industrial scenes, mounting steps as
follows:
Step 1
Check if the DIN-Rail mounting kit is installed firmly.
Step 2
Insert the bottom of DIN-Rail mounting kit (one side
with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Step 3
Check and confirm the product is firmly installed on
DIN-Rail, then mounting ends.
【Disassembling DIN-Rail】
Step 1
Power off device.
Step 2
After lifting the device upward slightly, first shift out
the top of DIN-Rail mounting kit, and then shift out
the bottom of DIN-Rail, disassembling ends.
Notes:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【Power Supply Connection】
12~48VDC power supply
Model I, V, VII devices of this series support
DC power input, and provide 3-pin terminals
with a spacing of 7.62 mm. The power supply
has non-polarity function. Voltage range:
12~48VDC. The pin definitions of power supply are shown as
follows:
PIN
1
2
Definition
V+
FG
48VDC power supply
Model III, IV devices of this series support DC
power input, and provide 3-pin terminals with
a spacing of 7.62 mm. The power supply has
anti-reverse connection function. Support
48V PoE, power range: 48VDC (44~55VDC). The pin
definitions of power supply are shown as follows:
PIN
1
2
Definition
V+
FG
AC power supply
Model II, VI, VIII devices of this series
support AC power input, and provide 3-pin
terminals with a spacing of 7.62 mm. Power
supply range: 220VAC (100~240VAC). The
pin definitions of power supply are shown as follows:
PIN
1
2
Definition
L
FG
Notice:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
and then plug the power supply plug contact and power
on.
Power OFF operation: First, remove the power plug,
and then remove the wiring section of terminal block.
Please pay attention to the above operation sequence.
【DIP Switch Settings】
This series provide 4-pin DIP switch for function
setting, where "ON" is the enabled end. DIP
switches definition as follows:
DIP
Definition
1
Jumbo frame
2
Flow Control
3
3
V-
One-key
VLAN
4
Reserved
[Checking LED Indicator]
The device provides LED indicators to monitor the device
3
working status with a comprehensive simplified
V-
troubleshooting; the detailed status of each LED is described
in the table as below:
LED
Indicate
ON
PWR
OFF
3
N
PoE(1-4)
ON
Operation
Set the DIP to ON to enable jumbo
frame function
Set the DIP to ON to enable flow
control function
Set the DIP to ON to enable VLAN
function. Copper port 1 is
interconnected with other
interfaces, and other ports except
copper port 1 are isolated from
each other.
-
Description
PWR is connected and running
normally
PWR is disconnected and running
abnormally
POE port is powering other devices
normally