ADDC MOBYL DATA CENTER 핸드북 - 페이지 8
{카테고리_이름} ADDC MOBYL DATA CENTER에 대한 핸드북을 온라인으로 검색하거나 PDF를 다운로드하세요. ADDC MOBYL DATA CENTER 11 페이지. Mobyl data center
Power Up/Down
/Fail Over
Press the main power button,
labeled MAIN PWR, to turn the
MDC22 on. If plugged into AC
or DC power, the batteries will
begin to charge (if installed). In
the event of power loss from
either the AC or DC power
inputs, the BioDigitalPC
/Mob-
®
ylPC cards will continue running
if the batteries are installed and
sufficiently charged.
Press the server power
button, labeled SERVER PWR,
to turn on the fans and the Bio-
DigitalPC
/MobylPC cards. Hold
®
the server power button for
approximately three seconds to
turn off the server power.
Press and hold the MAIN PWR
button for approximately three
seconds to turn off the MDC22
completely. This will stop the
batteries from charging (if bat-
teries are installed). Failure to
turn main power off may result
in the batteries slowly draining
(if installed).
Battery
DC Power
AC Power
Backplane Voltage Output Display
The MDC22 has a backplane voltage display to ensure
the power control is working properly. The reading
should be between 4.8 and 5.3 at all times. If the
reading is not at acceptable levels the MDC22 will
not work properly. Please ensure that you have the
proper input power levels in the appropriate AC/DC
inputs.