WIRING INSTRUCTIONS
WARNING:
Model 4137: Use 12-volt DC power source. Model 4138: Use 24-volt DC
power source. Higher DC voltage or AC voltage may cause serious damage
and/or personal injury.
Circuit must be properly fused to prevent possible fire hazard and/or damage
to pump and switch should the pump become jammed.
Caution:
All connections should be made using crimp-on connectors.
1. Electrical connections should be made as shown in Figure 4.
Figure 4
4-Amp. Model 4137
2-Amp. Model 4138
Two-Terminal, "On-Off" Type
Switch Can Be Attwood
Rocker, Push-Pull, or
Toggle Type
Sump System
2. Using butt connectors for 16-gauge wire, splice fuse holder into positive
lead (brown) in a location easily accessible for changing fuses. Install
the specified fuse.
3. Run brown wire from sump system directly to the positive (+) battery
terminal. If using manual on/off switch, run brown wire from sump system
to the switch, then to the positive (+) battery terminal.
4. Connect black wire from the sump pump system to the negative (-)
battery terminal to complete the circuit.
5. Re-connect power and water, and test unit for proper installation.
Feed water into the sump; if the flow appears to be too low, check
wire connections.
Note:
Reversed connections will result in opposite impeller rotation, which
drastically reduces capacity and can cause premature pump failure.
MAINTENANCE INSTRUCTIONS
Drain the unit during the winter months when not in use. Disconnect and
drain all lines to the unit. Remove hold-down clamps and empty the unit.
In some installations, it may be impossible to completely drain the system.
Add a non-toxic RV/marine antifreeze to the shower drain and circulate it
throughout the system.
For improved performance, periodically clean the filter. Remove the
cover and slip the filter out for easy cleaning. Re-install the filter and
cover when finished.
TROUBLE SHOOTING
Problem
Pump will not turn on
72" (183 cm)
Maximum Length
From (+) Terminal
to Fuse Holder
Brown Wire
+
Black Wire
DC Battery
12-Volt DC Model 4137
24-Volt DC Model 4138
Probable Cause
• Line is plugged
• Line is broken
• No power to the pump
• Fuse is blown
• System improperly wired
• Manual switch is not turned on
• Air is trapped in box—cover
needs to be vented
• Float Switch is jammed in
"off" position
Problem
Pump will not turn off
Pump output is low
System leaking at top
System is leaking at
inlet/outlet connection
Pump turns on but does not pump
Water returns to sump from
outlet hose
ATTWOOD LIMITED WARRANTY
ATTWOOD CORPORATION, 1016 North Monroe, Lowell, Michigan 49331
("Attwood") warrants to the original consumer purchaser that Attwood brand
products will be free from defects in materials and workmanship under normal
use and service for one year from the date of original consumer purchases.
This limited warranty is not applicable if the product has been damaged by
accident, improper installation, unreasonable or improper use, lack of proper
maintenance, unauthorized repairs or modifications, normal wear and tear,
or other causes not arising out of defects in materials or workmanship.
Attwood products are warranted for use on pleasure boats. Any other
use — including but not limited to commercial, racing, or non-marine
use — are not covered under this warranty. Attwood's obligation under this
warranty is limited to repair of the product at Attwood's plant or replacement
of the products at Attwood's option without expense to the original consumer
purchaser. Any expenses involved in the removal, reinstallation or transportation
of the product are not covered by this warranty.
The product must be returned to Attwood's plant at the address above,
postage prepaid, and insured with proof of original purchase including date.
If Attwood is unable to replace the product and repair is not commercially
practical or cannot be timely made, or if the original consumer purchaser is
willing to accept a refund in lieu of repair or replacement, Attwood may refund
the purchase price, less an amount for depreciation. The acceptance by
Attwood of any product returned or any refund provided by Attwood shall not
be deemed an admission that the product is defective or in violation of any
warranty. Products that are replaced or for which a refund is issued become
the property of Attwood.
THIS WARRANTY IS ATTWOOD'S ONLY EXPRESS WARRANTY OF
THIS PRODUCT. NO IMPLIED WARRANTY SHALL EXTEND BEYOND
ONE (1) YEAR FROM THE DATE OF ORIGINAL CONSUMER PURCHASE.
ATTWOOD SHALL NOT BE LIABLE FOR ANY DAMAGES FOR LOSS OF
USE OF THIS PRODUCT, NOR FOR ANY OTHER INCIDENTAL OR
CONSEQUENTIAL DAMAGES, COSTS OR EXPENSES.
Some states do not allow limitations on how long an implied warranty lasts
or the exclusion or limitation of incidental or consequential damages, so the
above limitations and exclusions may not apply to you. This warranty gives
you specific legal rights, and you may have other rights which vary from
state to state.
© 1998
Attwood
Subsidiary Steelcase Inc.
1016 N. Monroe Street, Lowell, MI 49331-0260
Probable Cause
• System improperly wired
• Float switch is jammed in
"on" position
• Box not mounted level
• Air is trapped in box—cover
needs to be vented
• System wired backwards
• Line is plugged/restricted
• Air is trapped in box—cover
needs to be vented
• Hose clamp is missing
• Hose clamp is loose
• Pipe connection is loose
• Line is plugged
• Outlet hose does not rise
continuously to thru-hull
• Check value plugged
or damaged