4. Power: Redundant, dual 12-48VDC power input
5. Environment working temperature: -40 75
Storage Temperature: -40 85
Relative humidity 5% 95%
DIN Rail Installation
In order to use in industrial environments expediently, the switch
adopt 35mm DIN-Rail installation, the installation steps as below:
1. Examine the DIN-Rail attachment
2. Examine DIN-Rail whether be firm and the position is
suitability or not.
3. Insert the top of the DIN-Rail into the slot just below the
stiff metal spring.
4. The DIN-Rail attachment unit will snap into place as shown
below.
Wiring Requirements
Cable laying need to meet the following requirements,
1. It is needed to check whether the type, quantity and
specification of cable match the requirement before cable
laying;
2. It is needed to check the cable is damaged or not, factory
records and quality assurance booklet before cable laying;
3. The required cable specification, quantity, direction and
laying position need to match construction requirements, and
cable length depends on actual position;
4. All the cable cannot have break-down and terminal in the
middle;
5. Cables should be straight in the hallways and turning;
6. Cable should be straight in the groove, and cannot beyond the
groove in case of holding back the inlet and outlet holes.
Cables should be banded and fixed when they are out of the
groove;
7. User cable should be separated from the power lines. Cables,
power lines and grounding lines cannot be overlapped and
mixed when they are in the same groove road. When cable is
too long, it cannot hold down other cable, but structure in the
middle of alignment rack;
8. Pigtail cannot be tied and swerved as less as possible.
Swerving radius cannot be too small (small swerving causes
terrible loss of link). Its banding should be moderate, not too
tight, and should be separated from other cables;
9. It should have corresponding simple signal at both sides of the
cable for maintaining.

Specification

Technology
Standard:
Support
IEEE802.3,
IEEE802.3u,
IEEE802.1Q, IEEE802.1p, IEEE802.1D/W
Protocol: ARP, ICMP, TCP, UDP, DHCP, DNS, HTTP, SW-Ring,
RSTP, SNMP
Flow control: IEEE802.3x, back pressure control
Function
Switch function: SW-Ring, QOS, 802.1QVLAN, RSTP, SNMP,
Port trunking, static multicast filter, port mirroring, port
flow statistics, upgrade online, up and download
configuration file, user name access system
SW-Ring: Support Single, Couple, Chain, Dual homing
Exchange attribute
100M forward speed: 148810pps
Transmit mode: store and forward
Switching fabric capacity: 1.0Gbps
MAC address table: 2K
Memory: 1Mbit
- 4 -
Interface
Electric port: 10Base-T/100Base-TX auto speed control, Half/full
duplex and MDI/MDI-X auto detect
100M optic fiber port: 100Base-FX, SC/ST/FC connector
Alarm port: 2 bit 7.62mm terminal block,
1 channel relay alarm output
Serial Port: RS-232 (DB9 male) or RS-485/422 (terminal block)
Serial
RS-232 signal: DCD, RXD, TXD, RTS, CTS, DTR, DSR, GND,
RI
RS-485 signal: D+, D-, GND
RS-422 signal: T+, T-, GND, R+, R-
Parity: None, Even, Odd, Space, Mark
Data bit: 5bit, 6bit, 7bit, 8bit
Stop bit: 1bit, 1.5bit, 2bit
Band rate; 300 115200bps
RS-232 connector: DB9 male
IEEE802.3x,
RS-485 connector: 5 bit terminal block
RS-485/422 power isolation and signal isolation: AC2500V
Transfer distance
Twisted cable: 100M (standard CAT5/CAT5e cable)
Multi-mode: 1310nm, 2Km
Single-mode: 1310nm, 20/40/60Km
1550nm, 80/100/120Km
RS-485/422: 1200m
RS-232: 15m
LED indicator
Run indicator: Run
Power supply indicator: PWR1, PWR2
Ethernet interface indicator: Link (1~5)
Serial port indicator: Tx (1~2), Rx (1~2)
Power supply
Input voltage: 12 48VDC
Type of input: 4 bit 7.62mm pitch terminal block