2.4. Limiters
swing gate requires a limiter in the OPEN and CLOSE directions. Stops protect the drive, gate and
fittings against wear. Operating the gate without permanently fixed stops leads to its malfunction. It is often
dangerous, this leads to premature wear and will invalidate the warranty!
90
Fig 5. Configurations of the gate opening limiters - a mechanical limit stop
on opening present in the gate and delivered with actuators.
The actuators are equipped with an internal actuator stroke limitation system consisting of adjustable and
independent mechanical end stops (figs. 5 and 6), one for the opening stroke and one for the closing stroke
(optional). The use of internal stops is convenient when there are no limit switches or when there is no other way
to limit the gate leaf stroke. Wherever possible, it is recommended to use gate stop limiters.
Fig. 6. Use of an additional set of mechanical limit switches in the actuators.
4
0
90
0
A
open
closed
B