ATX SignalOn N-M 18M0 Series 설치 및 운영 매뉴얼 - 페이지 8

{카테고리_이름} ATX SignalOn N-M 18M0 Series에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ATX SignalOn N-M 18M0 Series 20 페이지. Rf passive modules

CHAPTER 1: GENERAL DESCRIPTION
1.2.

Diplex Filter Module

SignalOn diplex filter modules allow for passive band splitting of both forward, and reverse signals. Each module houses
three separate diplex filter circuits. All circuit connections are accessible on the rear of the module housing. Attenuator pads,
and test points similar to splitter/combiner modules are not available on this module.
1.3.
Condition & Monitor Module
The condition and monitor module allows a signal to be passed through two make-before-break pad sockets before being
monitored by a –20 dB directional coupler. This allows a technician the ability to use one pad socket for padding and one pad
socket for equalization. A simplified Condition and Monitor schematic is shown in Figure 2.
1-2
EQ
MON
-20 dB
Figure #2: Condition and Monitor Module Schematic
PAD
INPUT
OUTPUT
SignalOn
Series – RF Passive Modules - Installation & Operation Manual
®
ATX Confidential & Proprietary