Aube Technologies TI032-3W 설치 및 사용자 설명서 - 페이지 2

{카테고리_이름} Aube Technologies TI032-3W에 대한 설치 및 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Aube Technologies TI032-3W 2 페이지. Aube technologies inc. programmable wall switch installation and user guide
Aube Technologies TI032-3W에 대해서도 마찬가지입니다: 설치 지침 및 사용 (2 페이지)

Aube Technologies TI032-3W 설치 및 사용자 설명서
Selecting the Operating Mode
The programmable switch has 2 operating modes: manual (MAN) and
automatic (AUTO). To switch mode, press the switch door for 3 seconds.
Manual Mode
The programmable switch operates as a regular switch.
Briefly press the switch door to turn the lights On or Off.
The mode (MAN) and state (ON or OFF) are displayed.
Automatic Mode
The programmable switch follows the programmed
schedule. The mode (AUTO), state (ON or OFF) and
current program number are displayed.
To temporarily override the programmed schedule,
press the switch door. The new state (ON or OFF) will
flash to show that this state is temporary. The override remains in effect
until you press the switch door again or until the beginning of the next
program.

Programming

You can set up to 7 programs. To set a program, you need to enter its
start time (ON) and its end time (OFF).
Pry the switch door open using a small screwdriver.
Press the PGM button to display a program and its
On or Off time. For example, when you first press
PGM, program number 1 (P1) and its On time
- : - -
(ON) will appear.
will appear instead of the
time if the program is not set (inactive).
Press the DAY button to select the day to which
you want to apply the program.
NOTE: If you want to apply the program to every
day of the week, press DAY until all the days are
displayed. (This still counts as 1 program, not 7)
Press the HOUR and MIN buttons to set the ON time (time when
you want the lights to turn on). If you have selected the 12-hour
format, ensure that PM appears on the screen when an afternoon
time is displayed.
After you have programmed the ON time, press the PGM button to
display the OFF time (time when you want the lights to turn off).
Repeat steps 3 through 5 to program the OFF
time. If the program ON time is set for every day of
the week, the program OFF time will automatically
be set for every day.
To set another program, repeat steps 2 through 6.
Programs that are not set will remain inactive.
Press one of the control buttons or close the switch door to return to
normal operation.
Clearing a Program
Press the PGM button until the desired program is selected. Hold the
PGM button for 3 seconds.
- : - -
Technical Specifications
Supply: 120 VAC, 50 / 60 Hz
Minimum
load: 40 watts
Maximum
load: 500 watts
Operating temperature
range: 5°F to 122°F (-15°C to 50°C)
Storage temperature
range: -4°F to 122°F (-20°C to 50°C)
Power
outage: The programs are protected by a rechargeable battery.
The screen is blank during the power outage.
Certifications: CSA & UL
TI032-3W
appears when the program is erased.
5.

Troubleshooting

Blank display
Faded or irregular
display
Cannot switch between
24-hour format and
12-hour format
Programs do not run as
expected
6.
The metal plate is hot
Warranty
AUBE warrants this product, excluding battery, to be free from defects in the work-
manship or materials, under normal use and service, for a period of three (3) years
from the date of purchase by the consumer. If at any time during the warranty
period the product is determined to be defective or malfunctions, AUBE shall repair
or replace it (at AUBE's option).
If the product is defective,
(i)
return it, with a bill of sale or other dated proof of purchase, to the place from
which you purchased it, or
(ii)
contact AUBE. AUBE will make the determination whether the product
should be returned, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall
not apply if it is shown by AUBE that the defect or malfunction was caused by dam-
age which occurred while the product was in the possession of a consumer.
AUBE's sole responsibility shall be to repair or replace the product within the terms
stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF
ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WAR-
RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PROD-
UCT. Some provinces, states or regions do not allow the exclusion or limitation of
incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS
PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS
WARRANTY. Some provinces, states or regions do not allow limitations on how
long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which
vary from one province, state or region to another.
Customer Assistance
7.
If you have any questions on the product installation or operation, contact us at:
705 Montrichard Avenue
Saint-Jean-sur-Richelieu, Quebec
J2X 5K8
Canada
Tel.: (450) 358-4600
Toll-free: 1-800-831-AUBE
Fax: (450) 358-4650
For more information on our products, go to
• Verify circuit breaker at main panel.
• Verify if light bulb is burned out
• Ensure the ON/OFF selector is at ON.
• Reset the switch using a paper clip.
• Load is less than 40 W
• Ambient temperature is below freezing
point
First, press one of the control buttons so
that MAN or AUTO appears on display.
• Make sure the switch is properly pro-
grammed.
- : - -
• Note that
indicates an inactive pro-
gram, 00:00 indicates midnight.
• If the switch has been configured for
12-hour format, check that PM appears on
the left side of the screen when an after-
noon time is displayed.
This is normal with high loads (maximum of
500 W).
www.aubetech.com
400-032-001-B
30/11/06
8.
9.
10.
2/2