Auber Instruments DSPR300 사용 설명서 - 페이지 2
{카테고리_이름} Auber Instruments DSPR300에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Auber Instruments DSPR300 12 페이지.
AUBER INSTRUMENTS
3.3 SSR output connection
The SSR control output of the DSPR300 provides a 12 VDC signal that can
control up to 5 SSRs in parallel. Connect terminal 7 to the positive pole of the
SSR (terminal 3 on Auber's SSRs). Connect terminal 6 to the negative pole of
the SSR (terminal 4 on Auber's SSRs). Please make sure the SSR is installed
on the heat sink with proper current rating.
4. Display Status
Power on
Display mode 1
80
100
Press down and
Hold for 5s
Exit
Knob
goto
Mash
Parameter settings
Figure 3. Display modes of DSPR300.
Display mode 1 (Normal operating mode): When power is turned on, the top
display window shows the current sensor temperature reading. When timer is
activated, the top display will be switched between the current temperature and
current time alternately. In mashing mode, the bottom display will show your set
temperature. In boiling mode, the bottom display will show your current output
percentage (e.g. P50 for 50% power output). Please check section 5 for how to
adjust set temperature/power.
Display mode 2 (Timer reset & Operation mode selection): This display
mode allows you to reset the timer, or to switch between the mashing and boiling
operation mode.
A short press of the knob will enter this display mode.
1) The display will show "rSt" on top and "n" at the bottom. This is the exit menu.
If you enter this mode by accident, you can press the knob again to exit this
display mode without changing anything.
2) Rotate the dial clockwise for one click will change the bottom display to "y".
This menu is to reset the timer. Press the knob will reset the timer. It has two
purposes. A) If you want to use the timer as regular timer without correlation to
the temperature, you can start the timer at any time by the reset button. B) After
timer is timed up and process ended, you can restart the process again by the
reset button instead of power off the system and power it on again.
3) Rotate the knob with two clicks, the top display will change to "Mode" and
bottom will show "Mash*". Rotate the knob again, the bottom display will change
to "boil". These two menus are for setting the controller to either mashing control
or boiling control mode. Press the knob will set the controller to the operation
mode displayed. Please check section 5.1 for details.
Display mode 3 (Parameter settings): Press down and hold the knob for 5
seconds to enter the display mode 3. Please check section 6 for details.
2021.05
Display mode 2
rst
Press
Knob
n
Exit
Timer reset /
mode selection
Display mode 3
Press
Next parameter
Knob
5. Operation
5.1 Operation mode selection
This controller offers two operation modes, mashing and boiling. When the
mashing mode is selected, the controller functions as a temperature controller.
It automatically adjusts the power output to hold the temperature at set point.
When boiling control mode is selected, the controller functions as a power
regulator. It allows the user to manually adjusting the power to control the
strength of the boil. Figure 4 shows how to select and switch between these two
modes.
Figure 4. Flow chart for timer reset & operation mode selection.
Press the knob once. The display will show "rSt". Rotate the knob with two clicks,
the top display will change to "Mode" and bottom will show "Mash*". Press the
knob will set the controller to mashing mode. When mashing mode is selected,
the yellow indicator on the top left corner of the panel will lit. This indicator will
be off if the boiling mode is selected.
Note: due to the limitation of 7 segment LED display, the letter "M" is displayed as "m".
5.2 Mashing Operation
When first powered up, make sure the controller is in the mashing mode: The
yellow colored mashing mode indicator on the upper left corner should be on,
and the bottom display has no "P" on the left. If not, please change the control
mode to mashing mode as discussed in section 5.1 above. If you were using the
controller in the mashing mode when powered off last time, the controller will
start in mashing mode.
After controller is powered up, the top LED displays the current temperature
reading from the sensor. If temperature sensor is not connected, it will show
"orAL". The bottom LED displays your set temperature. To adjust its value, just
rotate the knob. Once the value of the setting is changed, a small dot on the right
bottom corner will be flashing. It tells you that the setting has been changed but
not confirmed. After you adjust the temperature to the desired number, push the
knob to confirm the change. After confirmation, the new setting will remain on
the display and the dot will be turned off. If you forgot to push the dial, the display
will return to original set temperature after 2 seconds. The set point will remain
unchanged. This mechanism is for preventing temperature set point change by
accident.
WWW.AUBERINS.COM
P2/9