AUBER INSTRUMENTS
Power (24 VAC) is sent to terminal 9 and 10. The external switches on
terminals 2, 3, 4 and 5 should be momentary type. They are needed only if you
want to control the timer remotely. Otherwise, you can use the front keys on
the timer. The buzzer used in this example is also optional. The buzzer is
powered by the 24 VAC.
1
2
RST
3
MUT
4
START
5
Figure 3. Wiring example of JSL-73C-24.
9.2) Signal controlled by DC logic signal.
1
2
3
START
4
5
Figure 4. Rising-edge triggered signal.
1
START
2
3
e
10k
b
NPN
c
4
5
Figure 5. Inverted logic signal.