12) Firmware Upgrades: Mac
1) SYSTEM REQUIREMENTS
•
Apple Mac computer running OS 10.9 or later with 1 free USB port.
•
USB to FTDI cable (TTL-232R-5V): A suitable cable can be purchased directly from the
Abstract Data website or from any of the suppliers listed on the Abstract Data website.
Please note: This needs to be the 5V cable – *not* the 3.3V version.
Please note: Abstract Data cannot provide support for cables or programmers that do not fit this spec.
2) DOWNLOADS: http://www.abstractdata.biz/products/eurorack/3x/ade32/?tab=firmware
•
FTDI Cable Driver: This is the driver for the USB to FTDI cable – this only needs to be installed once.
•
Easy Uploader: This is the firmware installer – this only needs to be installed once.
•
Firmware files: These are the latest EEPROM and firmware versions that are unique to each upgrade.
3) UPGRADE PROCEDURE
•
Please note that this procedure will restore your ADE-32 to factory settings. Please consider making
a written record of any important settings you might currently have on the ADE-32 before upgrading.
•
Install the FTDI driver on the computer that you'll be using for the upgrade.
•
Install the Easy Uploader on the computer that you'll be using for the upgrade.
•
The ADE-32 needs to be plugged in via a standard Doepfer power cable – but *not* powered up.
You will also need access to the FTDI port (6x vertical pins) on the rear PCB of the ADE-32.
•
Carefully plug the FTDI cable in to the FTDI port (6x vertical pins) on the rear of the ADE-32.
The black wire on the FTDI cable faces down.
•
Ensuring the ADE-32 is in a secure position where none of the exposed components are likely to
touch other conductive surfaces – power up the ADE-32.
•
Plug the USB end of the USB to FTDI cable into the computer you will be doing the install on.
The ADE-32 might appear to stall a little as it is mounted – this is normal.
•
Open the application 'Easy Uploader'. If you get an 'unidentified developer message' – click 'OK'
and then open the application using a Control/Right Click – this will bring up a dialogue box –
click 'Open'. Check the correct USB port is selected – it will generally be the one on the bottom of
the list and will look something like: /dev/cu/usbserial-XXXXXXXX
•
EEPROM must be updated first. Click the 'Upload...' button, then navigate to and select the
ADE-32 EEPROM file you downloaded.
You will see the status message "Programming. Please wait..." followed by the status message
"Completed!". The unit will now be in a coma. This is normal.
•
Now update the firmware. Click the 'Upload...' button again, then navigate to and select the
ADE-32 firmware file you downloaded.
This part will take a bit longer – but you will see the status message "Programming. Please wait..."
followed by the status message "Completed!".
•
Quit the 'Easy Uploader', unplug the USB end of the cable from the computer, power-down
the ADE-32 and then carefully unplug the FTDI end of the cable from the ADE-32.
You have now completed the Firmware upgrade.