12) Firmware Upgrades: Mac

1) SYSTEM REQUIREMENTS

Apple Mac computer running OS 10.9 or later with 1 free USB port.
USB to FTDI cable (TTL-232R-5V): A suitable cable can be purchased directly from the
Abstract Data website or from any of the suppliers listed on the Abstract Data website.
Please note: This needs to be the 5V cable – *not* the 3.3V version.
Please note: Abstract Data cannot provide support for cables or programmers that do not fit this spec.
2) DOWNLOADS: http://www.abstractdata.biz/products/eurorack/3x/ade32/?tab=firmware
FTDI Cable Driver: This is the driver for the USB to FTDI cable – this only needs to be installed once.
Easy Uploader: This is the firmware installer – this only needs to be installed once.
Firmware files: These are the latest EEPROM and firmware versions that are unique to each upgrade.

3) UPGRADE PROCEDURE

Please note that this procedure will restore your ADE-32 to factory settings. Please consider making
a written record of any important settings you might currently have on the ADE-32 before upgrading.
Install the FTDI driver on the computer that you'll be using for the upgrade.
Install the Easy Uploader on the computer that you'll be using for the upgrade.
The ADE-32 needs to be plugged in via a standard Doepfer power cable – but *not* powered up.
You will also need access to the FTDI port (6x vertical pins) on the rear PCB of the ADE-32.
Carefully plug the FTDI cable in to the FTDI port (6x vertical pins) on the rear of the ADE-32.
The black wire on the FTDI cable faces down.
Ensuring the ADE-32 is in a secure position where none of the exposed components are likely to
touch other conductive surfaces – power up the ADE-32.
Plug the USB end of the USB to FTDI cable into the computer you will be doing the install on.
The ADE-32 might appear to stall a little as it is mounted – this is normal.
Open the application 'Easy Uploader'. If you get an 'unidentified developer message' – click 'OK'
and then open the application using a Control/Right Click – this will bring up a dialogue box –
click 'Open'. Check the correct USB port is selected – it will generally be the one on the bottom of
the list and will look something like: /dev/cu/usbserial-XXXXXXXX
EEPROM must be updated first. Click the 'Upload...' button, then navigate to and select the
ADE-32 EEPROM file you downloaded.
You will see the status message "Programming. Please wait..." followed by the status message
"Completed!". The unit will now be in a coma. This is normal.
Now update the firmware. Click the 'Upload...' button again, then navigate to and select the
ADE-32 firmware file you downloaded.
This part will take a bit longer – but you will see the status message "Programming. Please wait..."
followed by the status message "Completed!".
Quit the 'Easy Uploader', unplug the USB end of the cable from the computer, power-down
the ADE-32 and then carefully unplug the FTDI end of the cable from the ADE-32.
You have now completed the Firmware upgrade.
© 2016 Abstract Data Ltd.
Page 12 of 15
Version 1.1.3