Attention before mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【Wall-mounting the Device】
Step 1
Put the device on the wall it will be mounted as
reference or to refer to its mounting dimension, and
mark the locations of the 4 expansion screws.
Step 2
Mount the screws on the wall and reserve 7mm
void.
Step 3
Hang the device on the 4 expansion screws and
slide it down, then tighten the screws, mounting
ends.
【Disassembling the Device】
Step 1
Device powers off
Step 2
Unscrew the screws on the wall about 7mm.
Step 3
Lift the device then take it out, disassembling ends.
Note:
Power ON operation: first connect power line to the
connection terminal of device power supply, then power
on.
Power OFF operation: first unpin the power plug, then
remove the power line, please note the operation order
above.
【Power Supply Connection】
DC power supply
The series devices provide 1 power supply
input. The interface adopts M12 A-Coded 4-pin
needle (male) connector, which could be
connected to M12 A-Coded 4-pin slot (female).
Power supply range: 110VDC (70-160VDC).
The pin definitions of M12 (Male) are as follows:
No.
1
2
Definition
FG
V-
Description
Ground
Power
input
negative
【Relay Connection】
Such as: it's closed when power off, and send out alarm. This
series switches support 1 channel relay alarm information
output, support DC power alarm information or network
abnormal alarm output, it can be connected to alerting lamp,
alarm buzzer, or other switching value collecting devices for
timely warning operating staffs when alarm information occurs.
The pin definitions of relay are as follows:
No.
Definiton
【Console Port Connection】
(female). The pin definitions of M12 are as follows:
No.
Definition
Description
【Communication Interface Connection】
M12 100M Copper Port
3
4
V+
NC
Power
reserved
input
positive
No.
1
2
This device provides 1 M12 D-Coded 4-Pin slot
(female) for relay output. R1 and R2 is a pair of
normally open contacts of device alarm relay.
They are open circuit in normal non alarm state,
closed when any alarm information occurs.
1
2
3
4
R1
R2
NC
NC
This device provides 1 program debugging port
based on RS232, which could be connected to
PC for device CLI command management. The
interface adopts M12 D-Coded 4-pin slot
1
2
3
TX
RX
NC
RS-232
RS-232
Reserved
sending
receiving
signal
signal
This device provides 8 10/100Base-T(X) ports.
The interface type is M12 D-Coded 4-pin slot
(female). The pin definitions of M12 are as
follows:
Definition
Description
TD+
100M Ethernet transmitted
signal Positive
TD-
100M Ethernet transmitted
4
GND
Ground