Dametric BRM-DM2 사용자 설명서 - 페이지 7

{카테고리_이름} Dametric BRM-DM2에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dametric BRM-DM2 10 페이지. Gms basic refiner module

Dametric BRM-DM2 사용자 설명서
Dametric AB
5.6

Control motor

CMD Off/On/On+Al
CMD Screw pitch
CMD Low speed
CMD High speed
CMD Direction
CMD Drive curr.
CMD Hold curr.
CMD Min hold cu.
CMD Run current
5.7

Hydr.pressure. A

The parameters are valid for the hydraulic pressure measurement for control apart.
HPA Off/On/On+Al
HPA Al.lim.1 HH
HPA Al.lim.2 H
HPA Range
HPA Zero calibr.
HPA Span calibr.
5.8

Hydr.pressure. B

The parameters are valid for the hydraulic pressure measurement for control together.
Same as above but "HPA" is replaced by "HPB".
5.9

Temp fr. Bearing

The parameters are valid for the temperature measurement on the oil from the bearing.
OT1 Off/On/On+Al
OT1 Al.lim. 1HH
OT1 Al.lim. 2H
OT1 Zero calibr.
OT1 Span calibr.

5.10 Temp to Bearing

The parameters are valid for the temperature measurement on the oil to the bearing.
Same as above but "OT1" is replaced by "OT2".

5.11 Main motor power

MPM Off/On/On+Al
MPM Al.lim. 1LL
MPM Al.lim. 2L
MPM Al.lim. float
MPM Al.lim. filt.
MPM Range
MPM Type
MPM Zero calibr.
MPM Span calibr.
BRM-DM12 UM EN.docx
BRM-DM1/2
Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function.
Thread, set thread pitch in mm for the control rod (mm).
Rotor travel speed at low speed (mm/s).
Rotor travel speed at high speed (mm/s)
Direction, set 0 or 1.
Drive current (A).
Hold current (A).
Min limit for the current consumption in hold mode (A).
Actual current consumption (A).
Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function.
Alarm limit 1, high-high (ton).
Alarm limit 2, high (ton).
Range (ton).
Zero calibration, se calibration manual for actual measure system.
Span calibration, se calibration manual for actual measure system.
Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function.
Alarm limit 1, high-high (ºC).
Alarm limit 2, high (ºC).
Zero calibration, se calibration manual for actual measure system.
Span calibration, se calibration manual for actual measure system.
Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function.
Alarm limit 1, low-low (MW).
Alarm limit 2, low (MW).
Alarm limit, floating, level (MW).
Alarm limit, floating, filter time (s).
Range (MW).
Type, set 1.
Zero calibration, se calibration manual for actual measure system.
Span calibration, se calibration manual for actual measure system.
Feb. 18, 2020
User manual
Page 7 of 10