【LED Indicator】
LED indictor light on the front panel of product, the function of
each LED is described in the table as below.
LED
STATE
INDICATION
OFF
Power Off
PWR
(Power)
BRIGHT
Power On
OFF
Ethernet is not Connected
FX
(Fiber Link Port)
BRIGHT
Ethernet is Connected
OFF
10M Ethernet
100M
(10/100M)
BRIGHT
100M Ethernet
OFF
Not 1000M Ethernet
1000M
BRIGHT
1000M Ethernet
OFF
Half Duplex
DUP
(Duplex Mode)
FLASHING Full Duplex
OFF
Ethernet is not Connected
TP-TX
FLASHING Transmitting or Receiving Data
(Ethernet Port)
BRIGHT
Ethernet is Connected
【Installation】
Model3012 provides DIN-rail (optional accessories) and wall
mounting two types of installation.
Wall mounting installation
Unit: mm
DIN-Rail Installation
Wiring Requirements
Cable laying need to meet the following requirements,
1. It is needed to check whether the type, quantity and
specification of cable match the requirement before cable
laying;
2. It is needed to check the cable is damaged or not, factory
records and quality assurance booklet before cable laying;
3. The required cable specification, quantity, direction and
- 3 -
laying position need to match construction requirements, and
cable length depends on actual position;
4. All the cable cannot have break-down and terminal in the
middle;
5. Cables should be straight in the hallways and turning;
6. Cable should be straight in the groove, and cannot beyond the
groove in case of holding back the inlet and outlet holes.
Cables should be banded and fixed when they are out of the
groove;
7. User cable should be separated from the power lines. Cables,
power lines and grounding lines cannot be overlapped and
mixed when they are in the same groove road. When cable is
too long, it cannot hold down other cable, but structure in the
middle of alignment rack;
8. Pigtail cannot be tied and swerved as less as possible.
Swerving radius cannot be too small (small swerving causes
terrible loss of link). Its banding should be moderate, not too
tight, and should be separated from other cables;
9. It should have corresponding simple signal at both sides of the
cable for maintaining.
【Specification】
Standards: IEEE802.3, IEEE802.3u, IEEE 802.3ab, IEEE802.3z
Interface
Electric port: 10Base-T/100Base-TX/1000Base-TX auto speed
control, Half/full duplex and MDI/MDI-X auto detect
1000M optic fiber port: 1000Base-FX, SC/ST/FC connector
Transfer distance
Twisted cable: 100M (standard CAT5/CAT5e cable)
Multi-mode:850nm/1310nm, 500m/2Km
Single-mode: 1310nm, 10/20/40Km
1550nm, 60/80/100Km
Fiber optic cables:
Single Mode:8.3/125,8.7/125,9/125 or 10/125 um
Muti-Mode: 62.5/125, 50/125 um