DAMPP-CHASER Piano Life Saver System 설치 지침 매뉴얼 - 페이지 3
{카테고리_이름} DAMPP-CHASER Piano Life Saver System에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DAMPP-CHASER Piano Life Saver System 8 페이지. Backside vertical 8-part system which includes two humidifiers
DAMPP-CHASER Piano Life Saver System에 대해서도 마찬가지입니다: 설치 지침 (4 페이지), 설치 지침 매뉴얼 (9 페이지), 관리 및 유지보수 지침 (2 페이지)
STEP 1.
Move the piano into a position that enables you to reach both
the front and back without having to move the piano. When
you unpack the System box, you will notice items inside one of
the Humidifiers. To remove those items, first, remove the heater
bar which is mounted across the top of the Humidifier, then
remove the Humidistat, the Two-Light Panel, and the Single-
Light Cube which is in a separate plastic bag. Notice the Low
Water Sensor Probe mounted on the side of the Humidifier.
Replace the heater bar on the Humidifier. A Smart Bracket (SB)
is attached to this heater bar. The SB signals via a red light (the
Single-Light Cube) when the pads no longer wick water and
require replacement. The SB also turns off the Humidifier
heater bar when the pads fail or when the Humidifier runs out
of water.
The blue Humidifier pads are designed to wick water over
the heater bar, producing warm moist air currents which rise
and are circulated throughout the piano. Be sure all cords
are outside the Humidifiers then drape a pad across each
heater bar and push the pads down into the Humidifiers as
shown in Figure 1. Note the plastic Clean Sleeves ® on the
Humidifier Heater Bars. The sleeve protects the Heater Bar
from corrosion caused by excessive minerals in the water.
STEP 2. HUMIDISTAT INSTALLATION®
It should be noted that the two end vent holes on the top of the
Humidistat (above the Humidifier outlet) act as a "chimney" to
vent heat from the Humidistat. The holes should not be
obstructed in any way in the final installation.
Later in the installation you will need to plug the Water Sensor
probes telephone jack, the Smart Bracket phono jack, and the
Light Panel telephone jack into the jack outlets at the bottom of
the Humidistat. The Dehumidifiers and Humidifiers will also be
plugged into the Humidistat.
Remove the bottom panel. Read all of STEP 2 before deciding
where to locate the Humidistat.
Figure 2 shows the Humidistat hanging from the 6-inch tube
provided. To install the 6-inch tube,use 1/2" screws to mount
two C-Clips (Figure 3) 1-1/2" apart anywhere along the right
side of the keybed. Note: There should be at least 3 inches of
space on each side of the Humidistat to allow space for
plugging in cords.
FIGURE 1
FIGURE 2
3
Always mount the
Smart Bracket
probes outside the
plastic Sleeve.