WARM AIR SPEED ADJUSTMENT
• Switch off the power and remove the cover.
• Use Phillips screwdriver or flat notch.
The air speed is adjusted on the VR potentiometer.
Clockwise to increase air speed(+).
Counterclockwise to decrease air speed(-).
HEATING ELEMENT SWITCH
• Switch off the power and remove the cover.
• The heating element switch is located on the timer.
Adjust with a flat screwdriver:
• Slide switch to "ON" = heating element on.
• Slide switch to "1" = heating element off.
SENSOR RANGE ADJUSTMENT
• The sensor range is adjustable between 100mm and 230mm.
Standard range 130mm ± 20mm.
• Clockwise: To increase sensor activation range (+)
• Counterclockwise: To decrease sensor activation range (-)
• The sensor activation range should be adjusted to its environments,
e.g. light and distance to the bottom of the sink.
Note: Do not overturn the sensivity adjustment.
7