【Console port】
This series product provided 1pcs procedure test port based in
serial port. It adopts RJ45 interface, located in top panel, can
configure related command through RJ45 to DB9 female cable.
【Communication connector】
10/100BaseT(X) Ethernet port
The pinout define of RJ45 port display as below, connect by UTP
or STP. The connect distance is no more than 100m. 100Mbps is
used 120Ω of UTP 5, 10Mbps is used 120Ω of UTP 3, 4, 5.
RJ 45 port support automatic MDI/MDI-X operation. can connect
the PC, Server, Converter and HUB .Pin 1,2,3,6 Corresponding
connection in MDI. 1→3, 2→6, 3→1, 6→2 are used as cross
wiring
in
the
MDI-X
port
of
Converter
10Base-T/100Base-TX are used in MDI/MDI-X, the define of Pin
in the table as below.
NO.
MDI signal
1
TX+
2
TX-
1
8
3
RX+
6
RX-
4, 5, 7, 8
—
Note: "TX±"Transmit Data±, "RX±"Receive Data±, "—" Not use.
10/100Base-T(X) MDI (straight-through cable)
10/100Base-T(X) MDI-X (Cross over cable)
MDI/MDI-X auto connection makes switch easy to use for
customers without considering the type of network cable.
100Base-FX Fiber port
100Base-FX full-duplex SM or MM port, SC/ST/FC type .The
fiber port must be used in pair, TX (transmit) port connect remote
switch's RX(receive) port; RX(receive) port connect remote
switch's TX(transmit) port.
The optical fiber connection supports the line to instruct enhance
the reliability of network effectively.
Suppose: If you make your own cable, we suggest labeling the
and
HUB.
two sides of the same line with the same letter (A-to-A and B-to-B,
shown as below, or A1-to-A2 and B1-to-B2).
MDI-X signal
RX+
RX-
TX+
TX-
—
- 3 -
【LED Indicator】
LED indictor light on the front panel of product, the function of
each LED is described in the table as below.
System indication LED
LED
State
Description
Power is being supplied to power
ON
input PWR
PWR
(1~2)
Power is not being supplied to
OFF
power input PWR
When the alarm is enabled, power
ON
or the port's link is inactive.
Alarm
Power and the port's link is active,
OFF
the alarm is disabled.
System is not running well
ON/OFF
Run
System is running well
Blinking
ON
Port connection is active
Link/ACT
Data transmitted
Blinking
(1~8)
Port connection is not active
OFF
【Installation】
Before installation, confirm that the work environment meet the
installation require, including the power needs and abundant
space. Whether it is close to the connection equipment and other
equipments are prepared or not.
1. Avoid in the sunshine, keep away from the heat fountainhead or
the area where in intense EMI.
2. Examine the cables and plugs that installation requirements.
3. Examine whether the cables be seemly or not (less than 100m)
according to reasonable scheme.