AirVac AVP24000 설치 지침 - 페이지 2
{카테고리_이름} AirVac AVP24000에 대한 설치 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. AirVac AVP24000 2 페이지.
Overhead Vacuum Duct Installation (continued)
6 Secure the inlet valve to the valve bracket with the two
wall plate screws.
7 Repeat steps for each wall inlet valve location.
Under the Floor Installation
In homes with a pier and beam foundation or basement,
either the overhead or an under the floor installation can
be made. Sometimes under the floor installation is easier
in an existing home, especially if the roof has a low pitch
and clearances in the attic adds to the installation problem.
Under the floor installation also eliminates encountering
fire blocks in the wall. Shorter risers are also utilized,
eliminating the longer tube drop from the attic.
1 Vacuum tubing should be secured to floor joist with
perforated nailing strips or tube straps.
2 Generally, follow the overhead installation steps, but
from below the floor, to install each wall inlet valve.
Alternate Vacuum Duct Riser Installation
An effective technique highly suitable for many types
of construction with adequate working room inside the
attic is to make drops to the wall inlet valves through the
ceiling, then route the tube through the wall at inlet level
for the inlet valve on the opposite side of the wall. If this
method is used, the drop from the inside of the attic for the
riser can be made in the corner of a closet, utility room,
etc. where the tubing is not visible or not objectionable
to the Homeowner. On occasion this might be the only
alternative for placing an inlet valve in a desired location.
3 Power Unit Installation
Power Unit Unpacking and Pre-assembly
This AirVac power unit is packaged disassembled in a nested configuration which reduces the size of the shipping
carton and allows for much smaller shelf space requirements than previous AirVac models. The power unit must
be assembled during installation.
1 Carefully remove the nested vacuum from the box.
2 Separate each of the nested parts and place them
gently on the floor.
3 Refer to the parts identification figure below to
familiarize yourself with each of the parts.
VACUUM PARTS IDENTIFICATION
EXHAUST MUFFLER
EXHAUST ELBOW
INLET PLUG
MOUNTING
SCREWS
VACUUM BODY
BRACKET
CAUTION
Do not mount the motor head onto the vacuum
body until AFTER the vacuum body is hung on
the mounting bracket. Placing the motor head
on the vacuum body before mounting causes
the unit to be top heavy and may tip the vacuum
over, causing damage to the vacuum.
4 Connect the 90° steel exhaust elbow to the motor
head. The exhaust elbow can point to the left, right or
vertical depending on the installation requirements.
Secure the exhaust elbow to the motor head flange
with the #4 self‑tapping screw.
5 PLATINUM SERIES ONLY: Install the dust cone inside
the bottom end of the vacuum body as shown in the
figure. Be sure the cone snaps against the large ridge in
the vacuum body. DO NOT PUSH DUST CONE PAST
THE LARGE RIDGE!
6 PLATINUM SERIES ONLY: Install the slide‑gate collar
dust bag into the debris bucket. BE SURE TO FULLY
EXPAND THE BAG WITH YOUR HAND TO FILL THE
BUCKET.
Power Unit Mounting
1 Determine the mounting location for the power unit. Be
sure clearance dimensions are followed. The power
supply cord length is 5 feet. An AC power outlet of the
proper type on a dedicated circuit breaker must be
available within 5 feet so the power supply cord can be
directly plugged into the electrical outlet. DO NOT USE
AN EXTENSION CORD.
2 Use a stud finder to locate a wall stud for attaching the
mounting bracket. Mark the stud location.
3 Attach the mounting bracket to the wall, centered on the
marked stud, with the bottom edge 40" above the floor,
using the two 1/4" x 2" lag screws and a 7/16" socket.
4 Carefully hang the vacuum body by sliding the body's
mounting tab into the mounting bracket slot.
5 Fit the motor head onto the vacuum body with the
controls facing forward latching the two locking snaps.
6 Hang the debris bucket on the two bucket slide latches.
Swing the two slide latch handles up to lock the debris
bucket into place.
7 Slide the exhaust muffler onto the exhaust elbow.
Optional Exhaust Tubing
The vacuum's exhaust can be piped away from the
power unit if desired or required. The exhaust tubing
must vent to the outside of the house, NOT INTO THE
ATTIC. A louvered exhaust vent cap (VM136) is available
to terminate the exhaust tubing. Steel tubing is also
available for the exhaust tubing and may be required by
local building codes.
CAUTION
In order to avoid motor failure resulting from
excessive back pressure, DO NOT install more
than 30 feet of exhaust tubing and DO NOT
install any bends in the exhaust tubing closer
than 18" from the exhaust muffler.
1 Install any optional exhaust tubing following the
guidance above.
2 Connect the optional exhaust tubing to the muffler.
UNDER FLOOR INSTALLATION
INSTALL
VALVE BRACKET
12" TO 15" ABOVE
FLOOR LEVEL
PLATE
FLOOR
VM106
SWEEP TEE
FLOOR
JOIST
ALTERNATE DUCT RISER INSTALLATION
THE TUBING DROP
CAN BE INSIDE A CLOSET
TO WALL VALVE
THEN THROUGH THE
ON OTHER SIDE
WALL TO THE WALL
OF THE WALL
VALVE INSIDE THE ROOM
SLIDE-GATE COLLAR BAG
FLEXIBLE HOSE
(PLATINUM SERIES ONLY)
HOSE
CLAMPS
LAG
DUST CONE
DEBRIS BUCKET
(PLATINUM SERIES ONLY)
EXHAUST ELBOW & DUST CONE INSTALLATION
ATTACH THE EXHAUST
ELBOW TO THE MOTOR
HEAD WITH #4 SCREW
DO NOT PRESS
CONE PAST THE
LARGE RIDGE
EXHAUST ELBOW
CAN POINT TO
LEFT, RIGHT OR VERTICAL
DUST BAG INSTALLATION (PLATINUM SERIES ONLY)
EXPAND THE DUST
BAG BEFORE PLACING
IT INTO THE DEBRIS BUCKET
PLACE BAG'S
SLIDE-GATE
HERE
SLIDE-GATE COLLAR BAG
HANGING THE MOUNTING BRACKET & MOUNTING THE VACUUM BODY
ATTACH MOUNTING BRACKET
TO WALL WITH TWO LAG SCREWS
SCREW TO
WALL STUD
BOTTOM
EDGE 40"
ABOVE
FLOOR
INSTALLING THE MOTOR HEAD AND DEBRIS BUCKET
SNAP MOTOR HEAD
ONTO VACUUM BODY
RETAINING
SNAP
HANG DEBRIS
BUCKET ON BUCKET
SLIDE LATCHES
OPTIONAL EXHAUST TUBING
18" MINIMUM FROM
THE MUFFLER BEFORE
ANY BENDS IN THE
EXHAUST TUBING
EXHAUST TUBING
MUST VENT OUTSIDE
OF THE HOUSE
VM136
LOUVERED
EXHAUST
VENT CAP
Vacuum Intake Connection
Depending on the requirements of the installation, the
STUD
main vacuum duct line can be connected to the left or
right side intake port of the power unit.
1 Cut a 4" piece of duct tubing.
2 Slide the tubing piece into the left or right power unit
intake port. DO NOT CEMENT TUBING.
3 Slide a hose clamp onto the flexible hose. Slide the
flexible hose onto the tubing piece. Tighten the hose
clamp.
FLOW
4 Slide another hose clamp onto the flexible hose.
Connect the flexible hose to the drop from the main
MAIN VACUUM TUBE
vacuum duct system line. Tighten the hose clamp.
5 The unused power unit intake port MUST be sealed,
slide the inlet plug onto the unused intake port.
4 Power Unit Electrical
Low Voltage Control Wire Connection
1 Strip back the insulation about 1/2" from the two‑
HOLE IN
conductor low voltage control wire cable at the power
CEILING
unit.
2 Using a small screwdriver or other object, press down
RISER AND
CONTROL
on one of the wire locks on the control wire connector
WIRE
(top rear of motor head) while inserting the wire
into the connector hole. Release the wire lock while
holding the wire in. Repeat with the other wire and the
other hole. Polarity is not important, either wire can be
connected to either hole.
Grounding Instructions
This appliance must be grounded. If it should malfunction or breakdown, grounding provides a path of least
resistance for electrical current to reduce the risk of electrical shock. This appliance is equipped with a cord having
an equipment‑grounding conductor and grounding plug. The plug must be plugged into an appropriate outlet that
is properly installed and grounded in accordance with all local codes and ordinances.
WARNING
Improper connection of the equipment-grounding
conductor can result in risk of electric shock.
Check with a qualified electrician or service
person if you are in doubt as to whether the
outlet is properly grounded. Do not modify the
plug provided with the appliance - if it will not
fit the outlet, have a proper outlet installed by a
qualified electrician.
Power Connection
1 BE SURE THE UNIT'S POWER SWITCH IS OFF.
Plug the line cord into the AC receptacle.
2 Verify that power is available to the vacuum by
MOTOR HEAD
switching the unit's power on then off.
System Testing
TIP DUST CONE
The AirVac central vacuum system should be tested for good suction throughout the system. Use a vacuum gauge
INTO VACUUM BODY
(VM181) at each wall inlet valve location to measure the vacuum suction.
BOTTOM END
PRESS DUST CONE
5 Troubleshooting
IN UNTIL THE FOUR
TABS SNAP AGAINST
THE LARGE RIDGE
NOTE: NO USER SERVICEABLE PARTS INSIDE, DO NOT LUBRICATE MOTOR.
IF THE MOTOR FAILS TO OPERATE
1 Be sure the power unit is plugged into a working AC outlet.
2 Push breaker reset button on the power unit.
3 Check the panel circuit breaker that connects the power unit.
AFTER CHANGING OF THE BAG (PLATINUM SERIES ONLY)
1 Push down the RESET button for 7 seconds to reset the bag indicator.
IN CASE OF LOW VACUUM POWER
PLACE THE BAG INTO THE
1 Be sure that the inlet plug is inserted into the unused power unit intake port.
DEBRIS BUCKET AND
2 Check that all wall valves are closed.
EXPAND THE BAG AGAINST
THE DEBRIS BUCKET SIDES
3 Check that all gaskets on wall valves are sealed.
4 Check to see if debris bucket or bag (Platinum Series only) needs emptying.
5 Check for obstructions in the hose, tools, or vacuum lines.
6 Check for any ruptures or breaks in the vacuum duct system.
If you are unable to resolve the operational problems, please contact AirVac technical support at (800) 421‑1587.
6 Limited Warranty
Linear LLC warrants AirVac Platinum Series power units to be free of defects for
10 years, and AirVac Red Series power units to be free of defects for 5 years.
The warranty period begins from either (1) the date of "first user" purchase of
this product or (2) the first close of escrow date on a residence in which this
new product was originally installed. This warranty extends to the original user
HANG VACUUM BODY ON
of the product and to each subsequent owner of the product during the term of
MOUNTING BRACKET
this warranty. Linear LLC will repair or replace, at its option, parts and materials
at no charge. Parts supplied under this warranty may be new or rebuilt at the
option of Linear LLC.
If, during the limited warranty period, it appears as though this product contains
a defect which is covered by this limited warranty, call our toll free service
number before dismantling the product (1-800-421-1587). Remember to
attain a Return Product Authorization number (RPA) before returning any
product to Linear LLC. Send this product freight pre-paid and insured
to our service center for warranty repair. You will be advised on shipping
instructions when you call the toll free service number. Linear LLC will return
the repaired product freight pre‑paid within the U.S.A. The installing dealer or
distributor may assist you, at your choice and expense, with returning product
for repair. Please include a brief description of the problem and a dated proof‑
of‑purchase receipt with any product that is returned for warranty repair. ANY
PRODUCT RETURNED WITHOUT A RETURN PRODUCT AUTHORIZATION
NUMBER WILL BE REFUSED.
BUCKET
SLIDE
LATCH
SWING THE TWO
BUCKET SLIDE
LATCHES UP
OUTSIDE
WALL
Copyright © 2010 Linear LLC
VACUUM INTAKE CONNECTION
VACUUM
INTAKE PORT
HOSE
CLAMPS
LOW VOLTAGE CONTROL WIRE CONNECTION
LOW VOLTAGE
CONTROL WIRE
CONNECTOR
CAUTION
All circuit breakers must be SEPARATE and
DEDICATED as with any other major appliance.
The electrical outlets MUST match the plug
WITHOUT THE USE OF ADAPTERS. DO NOT USE
AN EXTENSION CORD.
AC POWER CONNECTION
BE SURE THE POWER
SWITCH IS OFF
THIS LIMITED WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR
OTHERWISE, AND OF ANY OTHER OBLIGATIONS OR LIABILITY ON THE
SELLER'S PART. THIS LIMITED WARRANTY DOES NOT COVER DAMAGE
CAUSED BY ACTS OF GOD, IMPROPER INSTALLATION, NORMAL
SYSTEM WEAR AND TEAR AS DEFINED BY THE MANUFACTURER, THE
VIOLATION OF APPLICABLE BUILDING OR ELECTRICAL CODES, OR
THE USE OF NON-AIRVAC WIRE, CABLE, OR WALL HOUSINGS. THIS
LIMITED WARRANTY APPLIES ONLY TO PRODUCTS INSTALLED IN A
PRIVATE RESIDENCE.
UNDER NO CIRCUMSTANCES SHALL THE SELLER BE LIABLE FOR
CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN
CONNECTION WITH USE, OR INABILITY TO USE THIS PRODUCT. IN
NO EVENT SHALL SELLER'S LIABILITY, FOR BREACH OF WARRANTY,
BREACH OF CONTRACT, NEGLIGENCE, OR STRICT LIABILITY, EXCEED
THE COST OF THE PRODUCT COVERED HEREBY. NO PERSON
IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN
CONNECTION WITH THE SALE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of consequential, incidental
or special damages, so the above limitation or exclusion may not apply to you.
This limited warranty gives you specific legal rights, and you may also have
other rights which vary from state to state.
www.purelypowerful.com
Manufactured by:
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
www.linearcorp.com
THE UNUSED
INTAKE PORT
MUST BE SEALED!
FLEXIBLE
HOSE
MAIN
INSERT THE INLET
VACUUM
PLUG ONTO THE
TUBE
UNUSED VACUUM
INTAKE PORT
LOW VOLTAGE
CONTROL WIRE
FROM WALL VALVES
PUSH EACH WIRE
LOCK DOWN WHILE
INSERTING THE WIRE
INTO THE CONECTOR
HOLE
PLUG THE POWER UNIT
INTO A GROUNDED
AC OUTLET THAT IS
WIRED TO A DEDICATED
CIRCUIT BREAKER
DO NOT USE AN
EXTENSION CORD
OR AN AC ADAPTER!
226529 B