When transporting the appliance, it must be firmly secured to avoid damage and when removed from the
vehicle placed gently on the ground.
When handling the appliance use the handles fitted, for heavier items it is recommended that two people are
utilised (one on each side). The appliance must be handled with care and attention to avoid any potential
damage.
When in use the appliance should have the locking castors secured and not be moved from the working
position.
When in storage the appliance must be situated away from extremes of temperature, humidity and moisture.
It is recommended that the appliance is inspected and tested for electrical safety and filter integrity by a
competent certification body every six months.
Electrical testing shall include, earth continuity and insulation resistance, filter testing measurements of
airflows, differential pressures and filter penetration.
Any contaminated filters arising from operating the appliance must be disposed of in impervious bags and in
accordance with current waste regulations.
For user servicing and maintenance, the appliance shall be dismantled , cleaned and serviced as far as is
reasonably practicable without causing risk to maintenance staff and others. Suitable precautions may include
decontamination prior to dismantling, provision for local filtered exhaust ventilation where the appliance is
dismantled, cleaning of the maintenance area and suitable personal protection
Product Description
This model is fitted with 2 stages of filtration -
HEPA filters, H13/H14 grade and Primary or Pre filter, G4 grade.
(Filter classification according to EN779, CENT TC195, EN 1822)
The fitting of a HEPA filter to this classification enables the appliance to be used for the collection of small
particle hazardous dusts.
Operating Instructions
As a general rule of thumb adopt the following procedure:
Set up the equipment as it would be used on the actual enclosure at the commencement of the job.
Take actual pressure gauge readings in normal use with clean filters and any ducting fitted, by means of
observation, measurement and judgement determine when the pre filters require changing and record the
gauge reading at this point.
This information will enable any future changes to be related to the actual observed pressure gauge readings.