F. CARE & MAINTENANCE OF YOUR GOBIDET™
THIS IS IMPORTANT
1. Clean your GoBidet™ PHS biweekly.
lubricate it with baby oil (or similar product) using a soft cloth.
G. TROUBLESHOOTING
1. Water will not turn on:
i.
Make sure water supply is connected AND turned on.
ii.
Make sure vertical water control stick (Part no. 2003.04) on
GoBidet™ is in cold water position. If hot water is not
installed and water control stick is in hot water position, water
will not flow.
iii.
Check-valve (Part no. 2003.04) may be installed backwards.
Disconnect braided "T" hose from GoBidet™. Using
needle-nose pliers or a tiny screw driver, remove retainer
"O" ring and check- valve with "O" ring ( There is an "O"
ring holding the check-valve in place and also one installed
on the check-valve). Insure proper positioning by referring
to parts diagram. Check-valve should be installed so that its
openings face inward in the direction of installation.
iv.
Make sure braided hose is not kinked or twisted.
2. Water leaks from connections:
i.
Turn water off and re-seal connections with Teflon tape. Turn
water back on and check for leaks. Repeat if necessary.
3. Water leaks from location where shower head assembly connects
to GoBidet™:
i.
Firmly tighten nut holding shower head assembly (Part no.
2003.01) to GoBidet™ .
4.
Water leaks from GoBidet™ behind the bell handle assembly
(Part no. 2003.04) :
i.
Insert screwdriver in hole at bottom of bell handle assembly
and loosen set screw to remove bell handle assembly.
Unscrew (counter clockwise direction) chrome nut cover
(Part no. 2003.24) from the front of the GoBidet™ housing.
This can usually be accomplished by hand.
ii.
Tighten (clockwise direction)
2003.45).
iii.
Replace chrome nut cover and bell handle assembly.
5. Can I operate my toilet if my GoBidet™ is disconnected?
i.
Yes, turn off water and disconnect GoBidet™ .
Place 3/8" compression cap w/ rubber washer (Part no.
ii.
2003.38 - included) onto "T" connector where GoBidet™ was
connected.
Turn water on to use toilet as normal.
iii.
After each cleaning,
large brass nut (Part no.
4