Installation
FOLLOW STRICTLY AND IN PRECISE ORDER THE FOLLOWING INSTALLATION
INSTRUCTIONS, OTHERWISE MAY RESULT AN ACCIDENTAL NEBULISATION OF
HARMFUL GAS
INSTALLATION OPERATIONS MUST BE DONE WITHOUT SPRAY CANS
1.
Unscrew the three screws of motor base (fig. 2) and remove it carefully: unplug the motor (CN2)
and end-line (CN7) connectors freeing the base, then set it aside (fig. 3).
Unplug the CN1 connector
2.
Fix the main case on wall using it as template for holes (fig. 3)
Peperosso must be fixed stably on a solid vertical wall, with appropriate dowels, in such a way that
the spray jet is as much as possible in the direction of any intruders
Peperosso can be installed ONLY in vertical position
Installation height can vary between 1,5 and 3 m
3.
Deactivate the control panel with tamper control excluded, set the battery and lock it with the
appropriate metal plate
4.
Plug the end-line CN7 and motor CN2 connectors
5.
Connect the battery
ATTENTION! By connecting the battery the motor move forward the plunger (leave it go
completely forward)
6.
Screw the three screws of the motor base
7.
Cable the CN1 connector according to the functioning mode will be used (instantaneous or driven
by IN3, see schemes at page 11 of this manuals)
Ensure the control panel provide the following commands to the connector (this is the minimum
configuration required for a secure behaviour of the system):
n°
Terminal
1
GND
2
+12V
3
T1
4
T2
5
IN1
6
IN2
7
IN3
9
+VS
Predisposition
GND
+ 12 V
Tamper line
Tamper line
+ 12 V
(BLOCK)
+ 12 V
(NEBULISATION READY)
This connection depends on functioning mode will be used:
connected to NC output of local detector for driven mode or to
remote surveillance interface
connected to IN2 for instantaneous mode
supply +12 V
for NC contact and powering the local detector /
surveillance interface
9