INSTALLATION
Step 5:
Hang the water heater onto
the bracket with outlet and
inlet pointed downward.
Make sure the water heater
is secured.
Plumbing Connections
ATTENTION
1. It is recommended that this water heater
be installed by a licensed and qualified
plumber in accordance with all applicable
national, state, and local plumbing codes.
2. DO NOT solder any pipes with unit
connected to pipes, heat from soldering can
cause permanent damage to internal parts.
3. Flexible water supply hoses(not provided)
comply with United Plumbing Code and
suitable for 194°F(90°C) water temperature
are recommended for plumbing installation.
4. When connecting the water pipes to inlet
and outlet connections, use two wrenches.
One wrench to hold the water heater fittings
and another wrench to tighten the connecting
pipes. Any over-tightening of the connecting
pipes can cause permanent damage to
internal components of water heater.
PG.10
5. It is recommended to install a manual shut-off
valve(not provided) at the inlet water connection
of the water heater to allow for easy shut-off
in the event that future maintenance or service
is needed.
6. This product does not use a storage tank
to maintain hot water, therefore a temperature
pressure relief valve (T&P) is not required for
most installations. However, in some locations
local codes may require a T&P valve for
installation. If one is required, install in
accordance with local codes and ensure it
operates correctly.
7. Only potable water can be used with this water
heater. Do not install in locations with pool or spa
water, or any locations where chemically treated
water can be introduced into the system.