Cascade 120C 설치 지침 매뉴얼 - 페이지 8
{카테고리_이름} Cascade 120C에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cascade 120C 10 페이지.
I
NSTALLATION
10
Cycle Fork Positioner functions
• Spread forks and close forks several times.
• Check for operation in accordance with ITA
• Check for leaks at fittings, valve, cylinders.
NON-SIDESHIFTING
A
Spread Forks
B
Close Forks
C
(not used)
D
(not used)
B
A
11
Adjust forks for equal movement
(if required)
NOTE: Attachment is Factory-adjusted for equal
fork movement when operated at recommended
pressure and flow rate.
A
B
C
D
6
Sideshift (if equipped) left and right. Check
for smoothness and equal movement.
(ISO) standards.
B
B
A
D
FP0204.ill
Locate cylinder 'T' fittings with flow restrictor
adjustment. Loosen jam nuts and screw
both flow restrictors in until they bottom.
Screw each restrictor out (CCW) three turns.
Spread forks fully, then close. Look for
unequal fork movement.
On faster fork (one that bottoms first), screw
flow restrictor in (CW) 1/2-turn.
Repeat Steps B and C until fork movement
is equal. Tighten jam nuts.
AUXILIARY VALVE FUNCTIONS
Check for compliance with ITA (ISO)
standards:
SIDESHIFTING
A
Sideshift Left
B
Sideshift Right
C
Spread Forks
D
Close Forks
A
D
FP0204.ill
C
Fork
Positioning
Cylinder
Flow Restrictor
Adjustment Screw
Hoist down
GA0005.ill
Hoist up
Tilt back
SIDESHIFTING WITH
SOLENOID VALVE
A
Sideshift Left
A
Spread Forks
(press knob button)
B
Sideshift Right
B
Close Forks
(press knob button)
C
B
B
A
C
Jam Nut
Front View
Tilt forward
A
C
B D
A
B
A
FP0204.ill
FP0194.ill
A
'T' fitting