Cascade 150H 설치 지침 매뉴얼 - 페이지 3
{카테고리_이름} Cascade 150H에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cascade 150H 11 페이지.
T
RUCK REQUIREMENTS
WARNING: Rated capacity of the truck/
attachment combination is a responsibility of the
original truck manufacturer and may be less
than that shown on the attachment nameplate.
Consult the truck nameplate.
Truck Relief Setting
2300 psi (160 bar) Recommended
2600 psi (180 bar) Maximum
Truck Flow Volume
150H
Fork
Fork
Position
Position
Sideshift
Cascade H-Series Fork Positioners are compatible with SAE
10W petroleum base hydraulic fluid meeting Mil. Spec. MIL-0-
5606 or MIL-0-2104B. Use of synthetic or aqueous base
hydraulic fluid is not recommended. If fire resistant hydraulic
fluid is required, special seals must be used. Contact Cascade.
Flow less than recommended can result in slow and unequal
fork movement.
Flow greater than maximum can result in excessive heating,
reduced system performance and short hydraulic system life.
Carriage Mount Dimension (A)
A
Class II
Class III 18.68 in. (474.5 mm)
Class IV 23.44 in. (595.5 mm)
GA0028.ill
Auxiliary Valve Functions
Check for compliance with ANSI standards:
GA0082.ill
217521 Rev. 0
Min.
Recommended
3 GPM
4 GPM
(11 L/min.)
(15 L/min.)
1 GPM
6 GPM
(4 L/min.)
(23 L/min.)
Minimum
14.94 in. (380.0 mm)
15.00 in. (381.0 mm)
18.74 in. (476.0 mm)
23.50 in. (597.0 mm)
Tilt
Forward
Sideshift
Hoist Down
Left
Hoist Up
Sideshift
Right
Tilt
Back
Max.
5 GPM
(19 L/min.)
12 GPM
(45 L/min.)
ITA (ISO)
Maximum
Spread
Forks
Close
Forks
Carriage
Clean carriage bars and inspect for
damaged notches.
GA0095.ill
1