Dancover GH108120 매뉴얼 - 페이지 5

{카테고리_이름} Dancover GH108120에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dancover GH108120 7 페이지. 2,2x2x1,9m

THE COMPONENTS OF TUNNEL CONSTRUCTION
1,98 m
1,77 m
1,68 m
1,65 m
1,58 m
1,10 m
0,96 m
0,88 m
0,79 m
0,60 m
* length tolerance of the tubes is within ± 1 cm
Corner T-piece
Tunnel T-piece
32/32/90
Tunnel T-piece
32/32/67
USER'S IMPORTANT INFORMATION
Proper use of the garden tunnel is provided by correct assembly as per the manufacturer's instructions:
1. The tunnel must be carefully assembled, as per the guidelines in the manual.
2. All elements of the tunnel construction should be carefully secured with tacks in the connections from all sides
3. The foil should be assembled on sunny and windless days, which will make the work considerably easier. Firm
4. During winter periods garden foil should be removed from the construction.
strengthen the tunnel by sticking metal or wooden poles and fasten them to the bows.
6. In longer tunnels additional reinforcement of the whole construction is recommended, through connection of
particular bows in their upper part with the use of an additional tube or a thick wire (the so-called ridge lath)
7. The tunnel's construction may additionally be reinforced using polypropylenic string that will be winding crossly the
tunnel's surface and that will be fastened to the metal hooks at the ground.
8. Don't leave the tunnel opened at strong wind, because it may cause the damage of particular parts of the tunnel.
9. One should not attach the strings supporting the plants to the bows, because it may cause the damage of particular
parts of the tunnel.
10. The garden tunnel should not be placed in the open space. It should be placed near the buildings or trees and
bushes.
11. During the assembly the ambient temperature should not be lower than 10°C.
THE MANUFACTURER is not responsible for improper use of the tunnel, other than intended use and for the
damages that occurred as a result of extreme weather conditions, such as strong wind, hailstorm, snow etc.
Three-layered foil
the tunnel's length
T00064
T00063
door frame height
door crossbar
T00077
bows
T00062
door height
T00061
T00058
the tunnel's width
horizontal elements
T00056
width over door frame
T00054
T00053
door width
door frame
T00051
T00001
T00005
T00030
Internal layer ensures increased thermal insulation properties, which results in keeping greater amount of thermal
radiation inside the tunnel.
External layers ensure:
proper elasticity, increased durability and resistance to damages and perfect permeability of light.
Advantages of three-layered foil
- perfect mechanic durability (addition of metallocene)
- perfect permeability of daylight
- high elasticity and resistance to low temperatures
- ensuring the greenhouse effect
2 pcs
4 pcs
2 pcs
9 pcs
4 pcs
4 pcs
10 pcs
2 pcs
4 pcs
4 pcs
4 pcs
28 pcs
8 pcs
Tunnel elbow
T00002
32/90
Tunnel hinge
T00006
The door frame
T00078
Four-way tunnel
T00004
piece
The pin to foil
T00008
Connecting
tube
T00033
Ø 28 x 0,2 m
Tacks
Assembly pins
8 pcs
6 pcs
2 pcs +
2 screws +
2 nuts
5 pcs
72 pcs
8 pcs
1 op
6 pcs