Cascade Turnafork 45E 설치 지침 매뉴얼 - 페이지 3
{카테고리_이름} Cascade Turnafork 45E에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cascade Turnafork 45E 14 페이지. Non-sideshifting & sideshifting clamps
Cascade Turnafork 45E에 대해서도 마찬가지입니다: 설치 지침 매뉴얼 (11 페이지)
T
RUCK REQUIREMENTS
WARNING: Rated capacity of the truck/
attachment combination is a responsibility of the
original truck manufacturer and may be less
than that shown on the attachment nameplate.
Consult the truck nameplate.
Truck Relief Setting
2300 psi (160 bar) Recommended
2600 psi (180 bar) Maximum
Truck Flow Volume
Min.
20E, 30E,
5 GPM
40E, 45E
(19 L/min.)
Cascade E-Series Carton Clamps are compatible with SAE 10W
petroleum base hydraulic fluid meeting Mil. Spec. MIL-0-5606 or
MIL-0-2104B. Use of synthetic or aqueous base hydraulic fluid
is not recommended. If fire resistant hydraulic fluid is required,
special seals must be used. Contact Cascade.
Flow less than recommended will result in reduced system
performance.
Flow greater than maximum can result in excessive heating,
reduced system performance and short hydraulic system life.
Carriage Mount Dimension (A)
A
Class II
14.96 in. (380.0 mm)
Class III 18.68 in. (474.5 mm)
GA0028.ill
Auxiliary Valve Functions
Check for compliance with ANSI standards:
GA0082.ill
Recommended
Max.
7.5 GPM
10 GPM
(28 L/min.)
(38 L/min.)
Minimum
Maximum
15.00 in. (381.0 mm)
18.74 in. (476.0 mm)
Tilt
Forward
Release
Sideshift
Hoist Down
Left
Hoist Up
Sideshift
Right
Clamp
Tilt
Back
ITA (ISO)
Carriage
Clean carriage bars and inspect for
damaged notches
GA0080.ill
1