Addie Water Systems IRON GENIE1 매뉴얼 - 페이지 9

{카테고리_이름} Addie Water Systems IRON GENIE1에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Addie Water Systems IRON GENIE1 19 페이지. Chemical free iron & sulfur reduction

Error
Error
Code
Type
0
Cam
The valve drive took
Sense
longer than 6 minutes
Error
1
Cycle
Step
Error
2
Regen
Failure
regenerated for more
3
Memory
Error
UD
Upper
Power failure install
Drive
programming change
Sync
Resets
Soft Reset: Press and hold the Extra Cycle and Down Buttons for 25 seconds while in normal service mode.
This resets all parameters. Check and verify all parameters in master programming.
Master Reset: Hold the Extra Cycle button while powering up the unit. This resets all parameters. Check and
verify all parameters in mater programming
Cause
to advance to the
next regeneration
position.
The control
experienced an
unexpected cycle
input
The system has not
than 99 days
Control board
memory failure
Troubleshooting
Unplug the unit and examine the power head. Verify that all
cam switches are connected to the circuit board and
functioning properly. Verify that the motor and drive train
components are in good condition and assembled properly.
Check the valve and verify that the piston travels freely.
Replace /reassemble the various components as necessary.
Plug the unit in and observe its behavior. The unit should cycle
to the next valve position and stop. If the error re-occurs,
unplug the unit and contact your water treatment dealer.
Unplug the unit and examine the power head. Verify that all
cam switches are connected to the circuit board and
functioning properly. Enter Master Programming mode and
verify that the valve type and system type are set correctly
with regard to the unit itself.
Step the unit through a manual regeneration and verify that it
functions correctly. If the error re-occurs unplug the unit and
contact you water treatment dealer.
Perform a manual regeneration to reset the error code.
Enter the Master Programming Mode and verify that the unit
is configure properly.
Perform a Master Reset and reconfigure the system via Master
Programming mode. After reconfiguring the system, step the
valve through a manual regeneration. If the error re-occurs
unplug the unit and contact your local water treatment dealer.
Valve will automatically recover.
Reset and Recovery