Danfoss 084B4081 설치 매뉴얼 - 페이지 10
{카테고리_이름} Danfoss 084B4081에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Danfoss 084B4081 16 페이지.
Menu survey
Menu set via display
Parameters
Function
Normal operation
Temperature (setpoint)
Thermostat
Differential
Max. limitation of setpoint setting
Min. limitation of setpoint setting
Temperature unit (°C/°F)
Correction of the signal from S4
Correction of the signal from S3
SEr: Manual control (-1), OFF: Stop control (0), ON:
Sta<rt control (1)
Displacement of reference during night operation
Define thermostat function
1=ON/OFF, 2=Modulating
Definition and weighting, if applicable, of thermostat
sensors - S4% (100%=S4, 0%=S3)
Time between melt periods
Duration of melt periods
Temperature setting for thermostat band 2.
As differential use r01
Definition and weighting, if applicable, of thermostat
sensors when night cover is on (100%=S4, 0%=S3)
Heat function
Neutral zone between refrigeration and heat function
Time delay when switching from refrigeration to heat
function
Food type: use settings listed in table
Min. limit for S4 temperature
Alarms
Delay for temperature alarm
Delay for door alarm
Delay for temperature alarm after defrost
High alarm limit for thermostat 1
Low alarm limit for thermostat 1
High alarm limit for thermostat 2
Low alarm limit for thermostat 2
Alarm time delay or signal on the DI1 input
Alarm time delay or signal on the DI2 input
Signal for alarm thermostat. S4% (100%=S4, 0%=S3)
Compressor
Min. ON-time
Min. OFF-time
Time delay for cut-in of comp. 2
Switch mode for 2 compressor operation.
= 1 sequentially. = Cyclic 2
Defrost
R-W
If the operation is limited by a setting of one or more passwords, reading and setting the parameter will be limited to:
R: This setting can be seen with password no. _ or higher.
W: This setting can be performed with password no. _ or higher (3 is the highest level).
*) In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
**) In order to change this parameter the parameter r12 Main switch must be set in position "SEr" allowing manual control of outputs.
10 | AN300028324304en-000401
Wiring diagram pages 2-4
R-W
Code
1
2
3
4
0-0
r00
1
1
1
1
1-2
r01
1
1
1
1
0-2
r02
1
1
1
1
0-2
r03
1
1
1
1
1-2
r05
1
1
1
1
1-2
r09
1
1
1
1
1-2
r10
1
1
1
1
0-2
r12
1
1
1
1
1-2
r13
1
1
1
1
1-2
r14
1
1
1
1
1-2
r15
1
1
1
1
1-2
r16
1
1
1
1
1-2
r17
1
1
1
1
0-2
r21
1
1
1
1
1-2
r61
1
1
1
1
1-2
r62
1
1-2
r63
1
1-2*
r89
1
1
1
1
1-2
r98
1
1
1
1
1-2
A03
1
1
1
1
1-2
A04
1
1
1
1
1-2
A12
1
1
1
1
1-2
A13
1
1
1
1
1-2
A14
1
1
1
1
1-2
A20
1
1
1
1
1-2
A21
1
1
1
1
1-2
A27
1
1
1
1
1-2
A28
1
1
1
1
1-2
A36
1
1
1
1
1-2
c01
1
1
1
1
1-2
c02
1
1
1
1
1-2
c05
1
1-2
c08
1
Min. value Max. value
5
6
7
8
9
1
1
1
1
1 "r03"
1
1
1
1
1 0.1 K
1
1
1
1
1 "r03"
1
1
1
1
1 -50°C
1
1
1
1
1 0/°C
1
1
1
1
1 -10 K
1
1
1
1
1 -10 K
1
1
1
1
1 -1
1
1
1
1
1 -50 K
1
1
1
1
1 1
1
1
1
1
1 0 %
1
1
1
1
1 0 hrs
1
1
1
1
1 0 min.
1
1
1
1
1 -50°C
1
1
1
1
1 0 %
1 0 K
1 0 min.
1
1
1
1
1 0
1
1
1
1
1 -50°C
1
1
1
1
1 0 min.
1
1
1
1
1 0 min.
1
1
1
1
1 0 min.
1
1
1
1
1 -50°C
1
1
1
1
1 -50°C
1
1
1
1
1 -50°C
1
1
1
1
1 -50°C
0 min.
1
1
1
1
1 0 min.
1
1
1
1
1 0 %
1
1 0 min.
1
1 0 min.
1 0 sec
1 1
SW = 2.0x
Factory
Actual
setting
setting
"r02"
2
20 K
2
50°C
50
"r02"
-50
1/F
0/°C
10 K
0
10 K
0
1
0
50 K
0
2
1
100 %
100
10 hrs
1
30 min.
5
50°C
2
100 %
100
50 K
5
240 min.
240
5
0
50°C
-50
240 min.
30
240 min.
60
240 min.
90
50°C
8
50°C
-30
50°C
8
50°C
-30
240 min.
30
240 min.
30
100 %
100
30 min.
0
30 min.
0
999 sec
5
2
2
© Danfoss | DCS (vt) | 2019.10