Danfoss AK-CC55 설치 매뉴얼 - 페이지 12

{카테고리_이름} Danfoss AK-CC55에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Danfoss AK-CC55 18 페이지. Single coil
Danfoss AK-CC55에 대해서도 마찬가지입니다: 설치 매뉴얼 (16 페이지)

Danfoss AK-CC55 설치 매뉴얼
Single Coil - continued
Real time clock
Defrost start via defrost schedule: 0/off=no.
1/on=yes
Six start times for defrost.
Setting of hours.
0=OFF
Six start times for defrost.
Setting of minutes.
0=OFF
Clock - Setting of hours
Clock - Setting of minutes
Clock - Setting of date
Clock - Setting of month
Clock - Setting of year
Defrost schedule for Mondays is active at On/1
Defrost schedule for Tuesdays is active at On/1
Defrost schedule for Wednesdays is active at On/1
Defrost schedule for Thursdays is active at On/1
Defrost schedule for Fridays is active at On/1
Defrost schedule for Saturdays is active at On/1
Defrost schedule for Sundays is active at On/1
Humidity
Setpoint for cut-in of humidity function
Difference for humidity function
Alarm limit for high humidity (too damp)
Alarm limit for low humidity (too dry)
Delay time for a humidity alarm
Humidity function during defrosting
Setpoint for RH% at input signal on 0 V
Setpoint for RH% at input signal on 10 V
Use humidity control
Miscellaneous
Delay of output signals after power failure
Input signal on DI1. Function:
0=not used. 1=status on DI1. 2=door function with
alarm when open. 3=door alarm when open. 4=defrost
start (pulse-signal). 5=ext.main switch. 6=night
operation 7=thermostat band changeover (activate
r21). 8=alarm function when closed. 9=alarm function
when open. 10=Appliance cleaning (pulse signal).
11=forced cooling at hot gas defrost, 12=Open night
cover. 14=Refrigeration stopped (forced closing).
15=case shutdown. 16=light. 20=Refrigerant alarm.
21= adaptive liquid control when short-circuited.
Network address
On/Off switch (Service Pin message)
IMPORTANT! o61 must be set prior to o04
(used at Lon 485)
Access code 3 (all settings)
Used sensor type: 0=Pt1000, 1=PTC1000, 2=Ntc5K,
3=Ntc10K. (S2 and S6 are not affected. They are always
Pt1000 ohms)
Max. hold time after coordinated defrost
Select signal for display view. S4%
(100%=S4, 0%=S3)
Pressure transmitter working range – min. value
Pressure transmitter working range – max. value
12 | AN294432763974en-000201
R-W
Code
1
2 3
4
1-2
t00
1
1
1
1
1-2
t01 -
1
1
1
1
t06
1-2
t11 -
1
1
1
1
t16
0-1
t07
1
1
1
1
0-1
t08
1
1
1
1
0-1
t45
1
1
1
1
0-1
t46
1
1
1
1
0-1
t47
1
1
1
1
1-2
t51
1
1
1
1
1-2
t52
1
1
1
1
1-2
t53
1
1
1
1
1-2
t54
1
1
1
1
1-2
t55
1
1
1
1
1-2
t56
1
1
1
1
1-2
t57
1
1
1
1
0-2
h23
1-2
h24
1-2
h25
1-2
h26
1-2
h27
1-2
h28
1-2* h29
1-2* h30
1-2* h31
1-2
o01
1
1
1
1
1-2* o02
1
1
1
1
1-3* o03
1
1
1
1
1-2
o04
1
1
1
1
3-3
o05
1
1
1
1
1-3* o06
1
1
1
1
1-2
o16
1
1
1
1
1-2
o17
1
1
1
1
1-3* o20
1
1
1
1
1-3* o21
1
1
1
1
5
6 7
8
9
Min.
1
1
1
1
1
0/off
1
1
1
1
1
0 hrs
1
1
1
1
1
0 min.
1
1
1
1
1
0 hrs
1
1
1
1
1
0 min.
1
1
1
1
1
1 day
1
1
1
1
1
1 mon.
1
1
1
1
1
0 years
1
1
1
1
1
0/Off
1
1
1
1
1
0/Off
1
1
1
1
1
0/Off
1
1
1
1
1
0/Off
1
1
1
1
1
0/Off
1
1
1
1
1
0/Off
1
1
1
1
1
0/Off
1
0 %
1
1 %
1
0 %
1
0 %
1
0 min.
1
0/Off
1
0 %
1
"h29"
1
0/Off
1
1
1
1
1
0 sec
1
1
1
1
1
0
1
1
1
1
1
0
1
1
1
1
1
0/Off
1
1
1
1
1
0
1
1
1
1
1
0/Pt
1
1
1
1
1
0 min.
1
1
1
1
1
0 %
1
1
1
1
1
-1 bar
1
1
1
1
1
6 bar
Max.
Fac.
Actual
1/on
0/off
23 hrs
0
59 min.
0
23 hrs
0
59 min.
0
31 days
1
12 mon.
1
99 years
0
1/On
1/On
1/On
1/On
1/On
1/On
1/On
1/On
1/On
1/On
1/On
1/On
1/On
1/On
100 %
70
30 %
5
100 %
100
100 %
0
240 min.
60
1/On
0/Off
"h30"
0
100 %
100
1/On
0/Off
600 sec
5
21
0
240
0
1/On
0/Off
999
0
3/N10
0/Pt
360 min.
20
100 %
100
5 bar
-1
200 bar
12
© Danfoss | DCS (vt) | 2019.07