EdgePoint PRO Installation Guide
______________________________________________________________________________
5.2
eFemto Location for Installation
The following list defines the eFemto location requirements for deployment inside the
building:
Flat 24"x24" wall space so a physical clearance of 5" on all sides of the device is
•
observed to ensure efficient operation of the cooling fans and antennas
A building support beam for mounting support (recommended)
•
Access to a AC power source and breakers to accommodate up to 15 amps / 120
•
VAC (ceiling access is recommended)
Access to an Ethernet port to connect the enterprise LAN line to the internet
•
backbone (ceiling access is recommended)
Must be within 15 ft (5m) from a window that has no metal sheeting with a clear
•
view of the sky
Moderate temperature between 32°F and 122°F
•
Dry environment with relative humidity between 0 to 95% non-condensing
•
Equipment needed for installation:
Drill or screwdriver with medium Phillips head
•
Step ladder to install and connect the cables
•
3 screws size #10 pan head x 2" with washer to install mounting plate
•
3 wall anchors optional (if required for wall mounting)
•
Figure 4 - Possible Mounting Location for an eFemto device
AirWalk Proprietary and Confidential
Ethernet
Power
connection
connection
GPS Antenna
< 15 ft (5m)
> 6 ft (2m)