Service Manual for Dry Channel HDC3/HDC6 Units
3. Remove the Control Board nuts from the four
studs.
4. Reverse the procedure to install a new Control
Board or Mylar Cover.
BEFORE ANY REPLACEMENT
PROCEDURE BEGINS, THE HDC3/
HDC6 MUST BE ISOLATED FROM
THE POWER SOURCE TO PREVENT
POSSIBLE ELECTRICAL SHOCK.
RELAY BOX
DANGER
Figure 8. Relay Box
Typically the Relay Box is mounted on the bottom
of the Dry Channel Tub on the right side. The actual
location may vary based on installation application
or cabinet configuration used.
1. Place the Main Power On/Off Switch in the off
position.
8
WARNING
POWER
ON
O
OFF
2. Remove the Dry Channel unit from its
power source. Use proper Lockout/Tagout
procedures.
3. Remove the four screws securing the Relay
Box to its mounting surface.
4. If complete Relay Box is to be replaced, tag
and disconnect wires.
5. Remove Relay Box.
6. Reverse procedure to assemble and install
Relay Box.
BEFORE ANY REPLACEMENT
PROCEDURE BEGINS, THE HDC3/
HDC6 MUST BE ISOLATED FROM
THE POWER SOURCE TO PREVENT
POSSIBLE ELECTRICAL SHOCK.
NOTE: The following Relay Box component
removal and replacement assumes the Relay Box
has already been removed from the Dry Channel
unit.
Figure 9. Exploded View of Relay Box