DUKER 4510 Series 사용 설명서 - 페이지 15

{카테고리_이름} DUKER 4510 Series에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. DUKER 4510 Series 19 페이지. Resilient seated butterfly valves

DUKER 4510 Series 사용 설명서
Move the disc (3) to the open position and remove the countersunk screws (27).
Remove the retaining ring (4) after removing the countersunk screws (27).
Replace profile sealing (9), remove soiling in sealing area. Check the exact location of the profile
sealing (9) in the retaining groove.
Fill threaded holes for the countersunk screws (27) with glass adhesive.
Tighten the countersunk screw (27) on the retaining ring (4) to the specified torque.
9 (new)
Move the valve disc (3) to the "CLOSED" position.
Pressure test; depending on the pressure level.
Issue 03
4
3
Düker GmbH – www.dueker.de
3
2
9 (used)
27
2
page 15