Danfoss 176F6636 애플리케이션 매뉴얼 - 페이지 3
{카테고리_이름} Danfoss 176F6636에 대한 애플리케이션 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Danfoss 176F6636 8 페이지. Door fan replacement for e1h/e2h drives vlt fc series fc 102, fc 103, fc 202, and fc 302
Danfoss 176F6636에 대해서도 마찬가지입니다: 설치 지침 (2 페이지)
Top Fan Kit for FA09-FA12/D3h-D4h/E3h-E4h
Application Guide
ELECTROSTATIC DISCHARGE
Electrostatic discharge can damage components.
-
Ensure discharge before touching internal frequency converter components, for example by touching a grounded, conduc-
tive surface or by wearing a grounded armband.
2.2 Top Fan Replacement
Select the fan replacement instructions based on the type of fan enclosure:
•
2.3 Removing the Top Fan and
•
2.5 Removing the Top Fan and Single Fan
•
2.7 Removing the Top Fan and Double Fan
2.3 Removing the Top Fan and Grill
To remove the top fan and grill, use the following steps. See
1.
Unfasten 2 screws (T25) and remove the front cover from the frequency converter.
2.
Unplug the top fan cable connector.
3.
Pull the top fan cable through the cable access hole, freeing it from the cabinet.
4.
Remove 2 screws (T25) from opposite corners of the top fan grill.
Danfoss A/S © 2022.03
N O T I C E
Grill.
Housing.
Housing.
Illustration
1.
AN389655468601en-000101 / 130R0767 | 3
Installation