cashco CA1 설치, 운영 및 유지보수 매뉴얼 - 페이지 5

{카테고리_이름} cashco CA1에 대한 설치, 운영 및 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. cashco CA1 10 페이지. Back pressure / relief regulators
cashco CA1에 대해서도 마찬가지입니다: 설치, 운영 및 유지보수 매뉴얼 (12 페이지)

cashco CA1 설치, 운영 및 유지보수 매뉴얼
VII. TROUBLE SHOOTING GUIDE
1. Erratic operation; chattering.
Possible Causes
A. Oversized regulator.
B. Worn plug.
2. Regulator inlet (upstream) too high:
Possible Causes
A. Regulator undersized.
B. Incorrect range spring (screwing in CW
of adjusting screw does not allow bringing
pressure level up to proper level.)
C. Too much rise (build).
3. Leakage through the spring chamber vent hole.
Possible Causes
A. Normal-life diaphragm failure.
B. Abnormal short-life diaphragm failure. B1. Can be caused by excessive chattering. See No.1.
4. Sluggish operation.
Possible Causes
A. Plugged spring chamber vent.
B. Fluid too viscous.
IOM-CA
SECTION VII
A1. Check actual flow conditions, re-size regulator for minimum and
maximum flow.
A2. Increase flow rate.
A3. Decrease regulator pressure drop; decrease inlet pressure by
placing a throttling orifice in inlet piping union.
A4. Install next step higher range spring. Contact factory.
A5. Before replacing regulator, contact factory.
B. Replace regulator.
A1. Confirm by opening bypass valve together with regulator.
A2. Check actual flow conditions, re-size regulator; if regulator has
inadequate capacity, replace with larger unit.
B. Replace range spring with proper lower range. Contact factory
C1. Review rise (build) expected.
C2. Contact factory.
A. Replace diaphragm.
remedy chatter.
B2. Can be caused by corrosive action. Consider alternate
diaphragm material.
B3. For composition diaphragms, assure not subjecting to over-
temperature conditions.
B4. Upstream (inlet) pressure build-up occurring that overstresses
diaphragms. Re lo cate regulator or protect with safety relief valve.
A. Clean vent opening.
B. Heat fluid. Contact factory.
Remedies
Remedies
Remedies
Remedies
to
5