AOM BRP 사용 및 유지 관리 매뉴얼 - 페이지 10
{카테고리_이름} AOM BRP에 대한 사용 및 유지 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AOM BRP 18 페이지.
USE AND MAINTENANCE MANUAL
3.1
INSPECTION OF PURCHASED PRODUCT
Inspect the spray gun before its use to check for damages caused by transportation or
improper storage. Make sure that all standard and optional components have been delivered.
3.2
INSTALLATION CONDITIONS
It is advisable to use dry compressed air to obtain the
best painting results.
To mount the hoses proceed as follows (use the drawing
below):
Connect the air inlet hose (RED hose) to the spray
+
gun 1/4" nipple (A). The compressed air must come
from a normal compressor with an operating pressure
of 4 bar (60 psi).
+
Connect the paint inlet hose to the spray gun
connection (3).
Select the most appropriate nozzle.
+
WARNING
Before you start using the equipment, make sure the
connections and hoses are in perfect working conditions,
that is without holes, bends or splits .
3.3
HOW TO USE THE SPRAY GUN
Adjust the fan with the regulator knob (1) (if the knob
+
is opened the fan becomes wider, if the knob is
closed the fan gets narrower).
+
Adjust the fan position by rotating the air cap (B).
+
Gradually open the fluid passage by turning the fluid
regulator knob (2) until the desired quantity is
obtained. Check the regulation on a smooth trial
surface until the desired fan width is obtained.
(1)
(B)
(3)
(4)
CAP
FAN POSITION
Page 10 of 13
®
(2)
(A)